AirMed PLUS ADS Intelligent User Manual

Anti-dekubitus-system intelligent

Advertisement

Page 1 of 23
1
Product description ..................................................................................................... 2
2
Operation the device .................................................................................................. 2
3
Operational location .................................................................................................... 4
4
Cleaning / Disinfection............................................................................................... 4
5
Maintenance ................................................................................................................... 5
6
Contra-indications ....................................................................................................... 5
7
"Turning on" the device...................................................................................................... 7
8
Screen the beginning after turning on the ADS intelligent ................................................ 8
9
Settings ............................................................................................................................. 10
9.1
Weight setting........................................................................................................... 10
9.2
Alarms-and warnings................................................................................................ 11
9.2.1
PMD and alternating/change pressure cycle mode .......................................... 11
9.2.2
Warnings........................................................................................................... 12
9.3
System-Settings ........................................................................................................ 13
9.3.1
Brightness ......................................................................................................... 13
9.3.2
Logic nurse call ............................................................................................... 13
9.3.3
key tone ............................................................................................................ 13
9.3.4
hour of use ........................................................................................................ 13
9.4
Time setup ................................................................................................................ 14
9.5
Date setup ................................................................................................................. 14
9.6
Touch calibration ...................................................................................................... 14
9.7
Languages ................................................................................................................. 14
9.8
Bedding mode........................................................................................................... 16
9.8.1
Bedding mode................................................................................................... 16
USER MANUAL
ADS intelligent
User manual for ADSI
Anti-Dekubitus-System Intelligent
Softwareversion: 0.95

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADS Intelligent and is the answer not in the manual?

Questions and answers

Summary of Contents for AirMed PLUS ADS Intelligent

  • Page 1: Table Of Contents

    Operational location ....................4 Cleaning / Disinfection....................4 Maintenance ........................5 Contra-indications ....................... 5 "Turning on" the device...................... 7 Screen the beginning after turning on the ADS intelligent ..........8 Settings ..........................10 Weight setting......................10 Alarms-and warnings....................11 9.2.1 PMD and alternating/change pressure cycle mode ..........
  • Page 2: Product Description

    2 Operation the device Connecting the device to the power supply. The ADS intelligent must connect to a power strip of 230 V/50Hz to operate. Other voltages or frequencies are not allowed, it can lead to damage of the device.
  • Page 3 Otherwise, there is danger that the maneuvarability of the bed and even the functionality of bed will be limited. In addition there is a danger of damage to the bed and/or the ADS intelligent system. Please note: You have to depend on the bed and mattress, the content of the so called “Bed...
  • Page 4: Operational Location

    If the electricity supply system has been switched off or has f ailed and the ADS intelligent was temporarily switched off, you have to turn the ADS intelligent on again to make sure, that the alarming system of the ADS int elligent will work fine.
  • Page 5: Maintenance

    5 Maintenance From the manufacturer no frequent maintenance is required for the ADS intelligent, but it is strictly recommendet to do it every year. However, this does not mean that requirements from other requirements, e.g. the repeat tests for electrical safety for electrical devices.
  • Page 6 USER MANUAL Page 6 of 23 ADS intelligent Softwareversion: 0.95...
  • Page 7: "Turning On" The Device

    USER MANUAL Page 7 of 23 ADS intelligent 7 "Turning on" the device After driving the main switch in position "I" the AirMed PLUS Logo and software-version of the device is shown for approximately two seconds. Softwareversion: 0.95...
  • Page 8: Screen The Beginning After Turning On The Ads Intelligent

    USER MANUAL Page 8 of 23 ADS intelligent 8 Screen the beginning after turning on the ADS intelligent 1. Shows that schematic image of the patient mattress colours are like:  red: pressure inside the cells is out of tolerance (±40%) ...
  • Page 9 USER MANUAL Page 9 of 23 ADS intelligent peaks that higher was the causing movement. The green line shows the level which needs to be reached to detect the movement of the patient. Will a movement be detected, the movement monitor shows an additional red dotted line to make an exception reporting more clear.
  • Page 10: Settings

    If you leave the menu by pressing the "√" button in the lower right corner, the chosen weight range will be saved. If you change the way setting, the ADS intelligent some time for adjusting the pressure. This will influence the sound and the schematic scheme of the mattress.
  • Page 11: Alarms-And Warnings

    9.2.1 PMD and alternating/change pressure cycle mode When the operator selects the PMD time of 30, 60 or 90 minutes, the ADS intelligent starts the patient movement monitor. The selected time the device will record and notice or movements of the patient.
  • Page 12: Warnings

    USER MANUAL Page 12 of 23 ADS intelligent Remark: the mode "alternating/change pressure cycle/change pressure cycle" is only able to choose if "PMD" is enabled and the chosen time the selected by eighter 30, 60 or 90 minutes. 9.2.2 Warnings In opposite to the "alarm", "warnings"...
  • Page 13: System-Settings

    USER MANUAL Page 13 of 23 ADS intelligent 9.3 System-Settings Inside this submenu the operator can set up the display brightness, to nurse call logic and the key-sound in case of pressing a key. By leaving the submenu by pressing the "√" button in the lower right corner all changes will be saved.
  • Page 14: Time Setup

    USER MANUAL Page 14 of 23 ADS intelligent 9.4 Time setup Please see chapter. 10 Set up Date and Time 9.5 Date setup Please see chapter. 10 Set up Date and Time 9.6 Touch calibration by using this function the touch screen will be calibrated. The operator needs to the crosses in the display within 10 seconds before touching the next cross.
  • Page 15 USER MANUAL Page 15 of 23 ADS intelligent Inside this submenu the operator can select one language. Softwareversion: 0.95...
  • Page 16: Bedding Mode

    USER MANUAL Page 16 of 23 ADS intelligent 9.8 Bedding mode In this operator can select between the normal mode, head-end-up position and bedding mode. 9.8.1 Bedding mode In this mode, the mattress will be inflated with full pressure for maximum 20 minutes. After 20 minutes the system turns into the previous mode automatically again.
  • Page 17: Movement History

    USER MANUAL Page 17 of 23 ADS intelligent 9.9 Movement history The movement history recorded movement data will be recorded day by day and shown in two rows, an upper row from midnight till 12 o'clock, and in one lower row from 12 to 24 o'clock.
  • Page 18: Set Up Date And Time

    USER MANUAL Page 18 of 23 ADS intelligent 10 Set up Date and Time 1. The current time will be shown. If the operator is changing the time, the current figure which is changed is highlighted in black colour. 2. By pressing this button (2) the new settings will be saved.
  • Page 19: Automatic Reaction Of Ads Intelligent

    USER MANUAL Page 19 of 23 ADS intelligent 11 Automatic reaction of ADS intelligent overpressure (+30%) : the system will automatically control valves to decrease the pressure level inside the mattress if necessary. Alternating/cycle time mode: this mode will automatically be enabled after passing by the first interval of patient monitoring a) without redistributing any movement of patient (please see chapter Error! Reference source not found.
  • Page 20: Data Export

    By the USB port of the device, the movement data can be transferred to a PC. To do this export, the tuned on -ADS intelligent must be connected to the USB port of a PC. The hard- drive of the ADS intelligent will be detected by the PC.
  • Page 21: Alarms And Warnings

    USER MANUAL Page 21 of 23 ADS intelligent 13 Alarms and Warnings Beside the optical symbols of alarms, alarms will be indicated also acoustically (and if enabled by the nurse call system). If an acoustic alarm will come up, you can see a bell into the display as well.
  • Page 22: Declaration Of Conformity

    2007/47/EC. The ADS clinic is consistent with risk class 1 based on annex IX rule 1 of the directives 93/42/EWG and 2007/47/EC. Applied standaards: DIN EN 980 DIN EN 1041 DIN EN ISO 14971 DIN EN 60601-1 DIN EN 60601-1 -1, -2, -4, -6, Bochum, 31.12.2015 Datum Geschäftsführer AirMed PLUS GmbH Softwareversion: 0.95...
  • Page 23 USER MANUAL Page 23 of 23 ADS intelligent manufacturer of ADS intelligent: AirMed PLUS GmbH Harpener Feld 34 D 44805 Bochum Germany Tel. 0049 (0)234 91773320 Fax 0049 (0)234 91773322 Email service@airmedplus.de Softwareversion: 0.95...