Beaufort Avola User Manual page 8

Table of Contents

Advertisement

PARAMETER SETTING
play enters the MENU state. In the speed field tC
is displayed. If you press + , a y is also displayed.
1 Items to be Set:
Now all temporary data, e.g. maximum speed
1 Data reset
(MAXS), average speed (AVG) and single-trip dis-
2 km/mile
tance (TRIP) can be cleared. Briefly press (< 0.3
3 Light sensitivity
seconds) to enter the km/mile setting interface.
4 Display backlight brightness
5 Automatic off time
If the user does not reset the data, the single
6 Maintenance warning settings
trip distance and the accumulated total riding
7 Input of the password
time will be automatically cleared when the
8 Wheel diameter selection
accumulated total riding time exceeds 99 hours
9 Setting speed limit
and 59 minutes.
Note: The data will not be cleared when the
2 Setting Preparation
display's lightsensing
When the display is active, press i twice (interval
function is set to 0 or when it is switched off.
< 0.3 seconds). The system will enter the MENU
4 km/mile
parameter setting state, in which the display pa-
rameters can be set. Press i twice again (interval
When the speed field displays S7, press +/- to
< 0.3 seconds) to return to the main menu.
switch between km/h and mph, or to set km
or mile.
In the parameter setting state, when the
parameter you want to set begins to flash, press
After this setting, briefly press i (< 0.3 seconds) to
/ to adjust the parameter value. Briefly press
enter the setting interface of light sensitivity.
to switch between the parameters to be set.
5 Light Sensitivity
Press twice (interval < 0.3 seconds) to exit the
When the speed field displays bL0, use +/- to
submenu. If no operation is performed for 10
choose a figure between 0 and 5. The higher the
seconds, the display will return to the normal
chosen figure, the higher the light sensitivity.
riding display.
After this setting, briefly press i (< 0.3 seconds)
3 Data Reset
to enter the setting interface of backlight
Press i twice (interval < 0.3 seconds) – the dis-
brightness.
14
6 Display Backlight Brightness
When the speed field displays bL1, press +/- to
choose a figure between 1 and 5. The figure 1 re-
presents the lowest brightness while 5 indicates
the highest display backlight brightness.
After this setting, briefly press i (< 0.3 seconds) to
enter the setting interface of automatic off time.
7 Automatic Off Time
When the speed field displays OFF, press+/- to
choose a figure between 1 and 9. The figures in-
dicate the minutes that it takes to automatically
shut down the display.
After this setting, briefly press i (< 0.3 seconds)
to enter the setting interface of maintenance
warning.
8 Maintenance Warning (can be deactivated)
When the speed field displays nnA, press +/- to
choose either 0 or 1. 0 disables the function
while 1 enables it.
After this setting, briefly press (< 0.3 seconds) to
enter the setting interface of password input.
The display will prompt maintenance necessity
based on such information as the accumulated
riding distance and the battery charge cycles.
• When the accumulated total riding distance
exceeds 5,000 km (can be customized by the
manufacturer), the display will show the symbol
. When SERVICE the display is started up, the
correct, the system will switch to the setting of
sign for accumulated riding distance will flash
the wheel diameter.
for 4 seconds, indicating that maintenance is
10 Wheel Diameter Selection
necessary.
When the speed position displays Wd, press +/-
• When the number of battery charge cycles
to select the correct wheel diameter: 16/18/20/
exceeds 100 (can be customized by the manu-
22/24/26, 700c, 28/29. The measurements are
facturer), the display will the symbol SERVICE.
in inches. A wrong wheel diameter can lead to
When the display is started up, the sign for
speed anomalies. After this setting, briefly press
battery will flash for 4 seconds, indicating that
(< 0.3 seconds) to enter the setting interface of
maintenance is necessary.
speed limit.
• The maintenance alert function can be
11 Speed Limit Setting
disabled: settings / maintenance alert (MA) /
When the speed field displays SPL, the distance
maintenance alert (MA) / 0. (Maintenance alert
field displays the value of the speed limit. Press
can also be set via a computer. This requires a
+/- i(< 0.3 seconds) to enter the menu of battery
USB connection. See also the parameter setting
communication.
instructions).
12 Battery Communication
9 Further Settings: Password Setting
The speed field displays b01 and the distance
When the speed field displays PSd, it is a
field displays the speed limit. Press i (< 0.3 se-
prompt to enter a password. Press +/- to set the
conds) to see the other information in sequence.
four-figure password (using digits 0 to 9). Briefly
After thissetting, press i twice (< 0.3 seconds) to
press i to
exit the menu.
switch between the single digits of the pass-
Note: Only when communication has been esta-
word. The default password is "0512". Briefly
blished between the battery and the controller
press to switch between the single digits of the
the following information will be displayed,
password. The default password is "0512". Briefly
otherwise the display will only show "- - - -".
press i to confirm your setting. If the set pass-
word is wrong, the system automatically returns
to the previous interface. If the set password is
13 Information on the battery menu
Left collumn: Information Displayed in the
Speed Field; Right collumn: Explanation
b01
current temperature
b02
maximum temperature
b03
lowest temperature
b04
total voltage
b05
current
b06
average current
b07
remaining capacity
b08
full capacity
b09
relative state of charge
b10
absolute state of charge
b11
charge/discharge cycle
b12
longest period without charge
b13
period since last charge
d01
voltage cell 1
d02
voltage cell 2
dn
voltage cell n
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

RicardoLicotaBassoSohoBelmonteDonne ... Show all

Table of Contents