Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Abstract Data Manuals
Control Unit
Event Boss ADE-33
User manual
Abstract Data Event Boss ADE-33 User Manual
Rhythm and pattern creation and manipulation
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Table Of Contents
16
page
of
16
Go
/
16
Contents
Table of Contents
Bookmarks
Table of Contents
Operation
Specifications
Module Overview
Front Panel
Rear Connections
Power Cable
Quick Start
Inputs and Outputs
Mode Select
Advertisement
Quick Links
Download this manual
ADE-33 EVENT BOSS
Rhythm and pattern creation and manipulation.
© 2018 Abstract Data Ltd.
http://www.abstractdata.biz
Version 1.0.1
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Related Manuals for Abstract Data Event Boss ADE-33
Control Unit Abstract Data ADE-51 User Manual
Vc ahdsr/ahd envelope generator (12 pages)
Summary of Contents for Abstract Data Event Boss ADE-33
Page 1
ADE-33 EVENT BOSS Rhythm and pattern creation and manipulation. © 2018 Abstract Data Ltd. http://www.abstractdata.biz Version 1.0.1...
Page 2: Operation
Global Mode 4: Logic Classic logic-based functionality Global Mode 5: Phase Phase shifting, time-based delays and swing-style effects Global Mode 6: Gates Trigger and gate-based manipulation and generation SPECIFICATIONS: Specs Hardware and spec overview © 2018 Abstract Data Ltd. Version 1.0.1...
Page 3: Module Overview
CV signal at input IN: GATE B/CV. • The ADE-33 has reverse-voltage protection built in – but please pay attention to the power supply and connection guidelines on Page 3 of this manual. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 4: Front Panel
Local Modes: B Event Input or CV input for all Local Modes OUTPUT LED Local Modes: Shows output status where On = High and Off = Low Local Modes: Output for all Local Modes © 2018 Abstract Data Ltd. Version 1.0.1...
Page 5: Rear Connections
The rear panel of the ADE-33 has exposed parts and connections. Please ensure when handling the ADE-33 that the unit is held by the sides of the front panel or the sides of the PCB (Printed Circuit Board). © 2018 Abstract Data Ltd. Version 1.0.1...
Page 6: Quick Start
Take the ‘Event’ signal you previously used at IN: MODE SELECT and insert it into IN: GATE A2. Gate A1/A2 selection can now be controlled via by either of the CV options available for this button. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 7: Inputs And Outputs
5) IN: GATE B/CV Input B for High (+5V) or Low (0V) signals or CV (0-5V) signals depending on Global Mode. 6) OUT High (+5V) or Low (0V) output for all Local Modes. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 8: Mode Select
• Click-Hold until one of the Mode LEDs 1-6 flashes quickly to enter the Button Edit Mode for this button. • Click-Hold again until the Mode LED stops flashing to exit the Button Edit Mode for this button. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 9
• 0-5V CV sets the variable <n> to a value of: 1 || 2 || 3 || 4 || 5 || 6 || 7 || 8. Operation • Toggles between Local Mode 4 and Local Mode 1. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 10
LOCAL MODE 6: Multiply /3 • 0-5V CV sets the multiplier <n> to a value of: 1 || 3 || 6 || 9 || 12. Operation • The output frequency is the input frequency multiplied by <n>. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 11
• An Event that is ‘tossed’ has a 50/50 chance it will ‘land’ High or Low. LOCAL MODE 6: Flip-Flop (Inversion) • 0-5V CV sets the probability percentage from 0-100%. Operation • The percentage chance that an input Event will be inverted at the output. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 12
• Input ‘A’ can be switched between A1 and A2 - manually or via CV. LOCAL MODE 6: XNOR • Standard 2x input Boolean Logic. Operation • Input ‘A’ can be switched between A1 and A2 - manually or via CV. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 13
LOCAL MODE 6: Percentage Mark/Space • 0-5V CV sets the Mark segment of the Mark/Space ratio from 0-100%. Operation • Adjusts the Mark/Space ratio of an input Event to become a percentage ratio of it’s own tempo. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 14
• Toggles between Local Mode 1 and Local Mode 2. LOCAL MODE 6: Logic Pass/Hold • 0-5V CV sets a variable value of <n> to 1/2/3/4/5/6/7/8. Operation • Toggles between Local Mode 3 and Local Mode 4. © 2018 Abstract Data Ltd. Version 1.0.1...
Page 15
CREDITS: Firmware Development: Paul Soulsby Beta Testing: Radek Rudnicki Thanks: Nigel Christopher Richard Devine Chris Meyer Alex Theakston Ben Wilson CONTACT: Justin Owen @ Abstract Data info@abstractdata.biz www.abstractdata.biz facebook.com/abstractdatabiz twitter.com/abstractdatabiz instagram.com/abstractdatabiz soundcloud.com/abstractdatabiz youtube.com/abstractdatabiz © 2018 Abstract Data Ltd. Version 1.0.1...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL