Bühler technologies AGF-FE-1 Installation And Operation Instructions Manual

Sample gas filter
Hide thumbs Also See for AGF-FE-1:

Advertisement

Quick Links

Gas Analysis
Sample gas filter
AGF-FE-1, AGF-FE-2
Installation and Operation Instructions
Original instructions
BE410009
Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen
06/2019
Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20
E-Mail: analyse@buehler-technologies.com
Internet: www.buehler-technologies.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGF-FE-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bühler technologies AGF-FE-1

  • Page 1 Gas Analysis Sample gas filter AGF-FE-1, AGF-FE-2 Installation and Operation Instructions Original instructions BE410009 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen 06/2019 Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 E-Mail: analyse@buehler-technologies.com...
  • Page 2 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 Internet: www.buehler-technologies.com E-Mail: analyse@buehler-technologies.com Read this instruction carefully prior to installation and/or use. Pay at- tention particularly to all advises and safety instructions to prevent in- juries.
  • Page 3: Table Of Contents

    AGF-FE-1, AGF-FE-2 Contents Introduction.............................................  2 Intended Use.........................................  2 Design types..........................................  2 Scope of delivery ........................................ 2 Safety instructions.........................................  3 Important notices........................................  3 General hazard warnings .................................... 4 Transport and storage ........................................ 5 4 Installation and connection ...................................... 6 Requirements to the installation site................................ 6 Connecting the gas lines .................................... 6...
  • Page 4: Introduction

    AGF-FE-1, AGF-FE-2 1 Introduction 1.1 Intended Use AGF-FE filters were designed specifically for front panel installation in analyzers or systems. All types can be used for filtering sample gas. Please note the specifications in the data sheets on the specific intended use, existing material combinations, as well as pres- sure- and temperature limits.
  • Page 5: Safety Instructions

    AGF-FE-1, AGF-FE-2 2 Safety instructions 2.1 Important notices Operation of the device is only valid if: – the product is used under the conditions described in the installation- and operation instruction, the intended application according to the type plate and the intended use. In case of unauthorized modifications done by the user Bühler Technolo- gies GmbH can not be held responsible for any damage, –...
  • Page 6: General Hazard Warnings

    AGF-FE-1, AGF-FE-2 2.2 General hazard warnings The equipment must be installed by a professional familiar with the safety requirements and risks. Be sure to observe the safety regulations and generally applicable rules of technology relevant for the installation site. Prevent malfunctions and avoid personal injuries and property damage.
  • Page 7: Transport And Storage

    AGF-FE-1, AGF-FE-2 3 Transport and storage The device should be only transported in the original case or in appropriate packing. If the device is not used for some time, protect it against heat and humidity. Store the device in a roofed, dry, and dust free room.
  • Page 8: Installation And Connection

    AGF-FE-1, AGF-FE-2 4 Installation and connection 4.1 Requirements to the installation site The front plate has to be prepared according to the drawings in the data sheets. The filter should be installed in a way so the filter element can be replaced. If the filter protrudes from a contour, please note this poses a risk of damage.
  • Page 9: Operation And Control

    AGF-FE-1, AGF-FE-2 5 Operation and control NOTICE The device must not be operated beyond its specifications. BE410009 ◦ 06/2019 Bühler Technologies GmbH...
  • Page 10: Maintenance

    AGF-FE-1, AGF-FE-2 6 Maintenance During maintenance, remember: – The equipment must be maintained by a professional familiar with the safety requirements and risks. – Only perform maintenance work described in these operating and installation instructions. – When performing maintenance of any type, observe the respective safety and operation regulations.
  • Page 11: Service And Repair

    AGF-FE-1, AGF-FE-2 7 Service and repair This chapter contains information on troubleshooting and correction should an error occur during operation. Repairs to the unit must be performed by Bühler authorised personnel. Please contact our Service Department with any questions: Tel.: +49-(0)2102-498955 or your agent If the equipment is not functioning properly after correcting any malfunctions and switching on the power, it must be inspected by the manufacturer.
  • Page 12: Disposal

    AGF-FE-1, AGF-FE-2 8 Disposal Dispose of parts so as not to endanger the health or environment. Follow the laws in the country of use for disposing of elec- tronic components and devices during disposal. Bühler Technologies GmbH BE410009 ◦ 06/2019...
  • Page 13: Appendices

    AGF-FE-1, AGF-FE-2 9 Appendices 9.1 Technical Data Built-in filter AGF-FE-1 AGF-FE-1-T AGF-FE-2 Filter surface 40 cm² 40 cm² 13 cm² Filter fineness 2 µm 2 µm 8 µm Dead volume 25 ml 25 ml 6 ml Material - filter housing PVDF / 1.4571...
  • Page 14: Attached Documents

    AGF-FE-1, AGF-FE-2 10 Attached documents – RMA - Decontamination Statement Bühler Technologies GmbH BE410009 ◦ 06/2019...
  • Page 15 RMA-Formular und Erklärung über Dekontaminierung RMA-Form and explanation for decontamination RMA-Nr./ RMA-No. Die RMA-Nummer bekommen Sie von Ihrem Ansprechpartner im Vertrieb oder Service./ You may obtain the RMA number from your sales or service representative. Zu diesem Rücksendeschein gehört eine Dekontaminierungserklärung. Die gesetzlichen Vorschriften schreiben vor, dass Sie uns diese Dekontaminierungserklärung ausgefüllt und unterschrieben zurücksenden müssen.