iC-PZ AN1
GETTING STARTED GUIDE iC-PZ
Automatic analog adjustment
• In tab 'Signal Conditioning' section 'Analog Adjust-
ment' set
AC_COUNT = '0d08' [ = 0x08]
AC_SEL1 = '15 (default)' [ = 0x0F]
AC_SEL2 = 'Best but longest auto-calibration'
[ = 0x00]
Automatic digital adjustment
• In tab 'Signal Conditioning' section 'Digital Adjust-
ment' set
AC_COUNT = '0d08' [ = 0x08]
AC_SEL1 = '15 (default)' [ = 0x0F]
AC_SEL2 = 'Best but longest auto-calibration'
[ = 0x00]
• Rotate/ move at least at minimum speed required for
• Send command AUTO_ADJ_ANA to execute auto-
Figure 9: Automatic analog adjustment
• Rotate/ move at least at minimum speed required for
• Send command AUTO_ADJ_DIG to execute autocali-
Figure 10: Automatic digital adjustment
the automatic analog adjustment. The following val-
ues are recommended:
Rotary (iC-PZ2656): 300 RPM
Linear (iC-PZ205): 25.6 cm/s
calibration.
the automatic digital adjustment. The following values
are recommended:
Rotary (iC-PZ2656): 300 RPM
Linear (iC-PZ205): 25.6 cm/s
bration.
Rev A1, Page 7/10