LCP9H and LCP9HW
Local Control Panels for VG9000H
Rev. 1.1
Installation, Maintenance and
Operating Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Metso LCP9H

  • Page 1 LCP9H and LCP9HW Local Control Panels for VG9000H Rev. 1.1 Installation, Maintenance and Operating Instructions...
  • Page 2: Table Of Contents

    7 LCP9H 70 en Table of Contents LCP9H and LCP9HW Local Control Panels for VG9000H............ 3 General ..........3 Technical description......3 System architecture ....... 3 Markings ..........3 Technical specifications ......3 Recycling and disposal ......4 Safety precautions ......... 4 TRANSPORTATION, RECEPTION AND STORAGE............
  • Page 3: Lcp9H And Lcp9Hw Local Control Panels For Vg9000H

    All the buttons are lockable with e.g. padlock (max. valve controller. Later on in this manual LCP9H_ name is shackle dia. 5 mm). used when both versions (LCP9H and LCP9HW) are in question. This manual only describes the Local Control System architecture Panel LCP9H_ wiring, configurations and functions.
  • Page 4: Recycling And Disposal

    7 LCP9H 70 en Maximum distance for power supply: Recycling and disposal 1200 m Most local control panel parts can be recycled if sorted Ex ia IIC T4/T5/T6 Gb: according to material. Most parts have material mark- Ui ≤ 9.8 V ing.
  • Page 5: Electrical Connections

    4.1.1 Open / Close button Close (red) ❑ Test (amber) ❑ This functionality is only available in LCP9H. ❑ Alarm (red) LCP9HW does not have the valve close/open functionality. ❑ The purpose of the Open / Close button is to manually close or open the valve depending on the assembly and configuration of the valve;...
  • Page 6: Maintenance

    ❑ The Alarm LED will blink, if the communication details. between the LCP9H and the VG9000H is discon- ❑ The manual test via LCP9H uses the same stroke nected or not functional, or if the External size than manual programmed...
  • Page 7: Trouble Shooting

    7 LCP9H 70 en TROUBLE SHOOTING If the LCP9H does not work, check the following: ❑ Check the LCP parameter in the VG9000H: The LCP parameter in the VG9000H needs to be enabled. Go to the parameters menu in the VG9000H and check that LCP is enabled.
  • Page 8: 10 Dimensions

    7 LCP9H 70 en DIMENSIONS Note: This button is only available in LCP9H. LCP9HW does not have this button. Metso Automation Inc. Europe, Levytie 6, P.O. Box 310, 00811 Helsinki, Finland. Tel. +358 20 483 150. Fax +358 20 483 151 North America, 44 Bowditch Drive, P.O.