Pleora Technologies Inc. (Pleora) customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Pleora for any damages resulting from such improper use or sale.
Table of Contents Introduction ..................5 Overview of the iPORT PT1000-CL..........6 Highlights......................6 Models......................... 6 Characteristics and Features ................7 Connectors................... 9 Camera Link Connector ..................9 Power and IO Connectors ................. 10 3.2.1 Power Connector for OEM Board Set ............10 3.2.2 IO Connector for OEM Board Set ..............
2.0 Overview of the iPORT PT1000-CL 2.1 Highlights The iPORT PT1000-CL IP Engine delivers the core set of features offered in all iPORT IP Engines, plus a connector and extended functions tailored specifically for Camera ® Link cameras. It interfaces to all cameras that comply with the Camera Link base configuration standard.
3.0 Connectors This section provides information about the Camera Link, power, and IO connectors on the OEM and boxed versions of the iPORT PT1000-CL IP engine. The Ethernet connector is a standard RJ-45 plug. 3.1 Camera Link Connector All iPORT PT1000-CL models use the same high-density, 26-pin MDR26 standard female Camera Link connector.
3.2.3 Power Connector for Boxed Unit The iPORT PT1000-CL boxed units both use the same Hirose 6-pin power connector shown in Figure 2. The part number is HR10A-7R-6P. The mating part number is HR10A-7P-6S. Table 6 lists the six pins in the connector and describes the function of each.
4.0 Signal Handling The iPORT PT1000-CL handles the signals in much the same way as other iPORT IP engine models. There are a few minor differences, which are described in this section. 4.1 PLC Control Blocks The Programmable Logic Controller (PLC) in the iPORT PT1000-CL routes signals through a sophisticated PLC Control Block.
Table 9 and Table 10 list the PLC input and output programming signals that are specific to the iPORT PT1000-CL IP engine. The labels used for inputs to the PLC Lookup Table depend on the input configured in the PLC Lookup Table dialog.
4.3.2 Camera Controls The iPORT PT1000-CL can send commands to cameras through the Camera Link camera control signals. The Camera Link specification provides four camera control signals, which can be used in a variety of ways. For information on how your camera uses them, refer to its documentation.
±0.005 5.1 Mechanical Drawings of OEM Board Set Figure 6 to Figure 8 are mechanical drawings of the iPORT PT1000-CL OEM boards. The main board and daughter board are both 0.0625 inches thick. The maximum secondary component height on both boards is 0.08 inches, unless otherwise specified in the drawings.
This appendix is a brief overview of the features and PLC block in the iPORT PT1000- CL2 IP Engine, the first-generation version of the iPORT PT1000-CL. This model is not available to new customers and is not being upgraded with new features. Table 11 lists its key characteristics and features and Figure 13 shows its PLC Control Block.