Keystone Figure 952 KniFe gate ValVes
InstallatIon and operatIng manual
installation instruCtions
note
Heavy valves will require a chain block or crane to
assist. in difficult locations, large cylinder actuators
can be removed from valve and re-fitted after
installation if necessary, but check cylinder to gate
alignment carefully and that valve seats correctly.
(refer cylinder fitting instructions).
1. Close valve.
2. Check valve size is correct and that there is
adequate clearance to install valve.
3. Check flange faces are clean and smooth
and that bolt hole patterns on pipe flanges
are the same as the valve, and are in line.
4. Check bolt sizes and threads are
clean and compatible with the valve.
(separate technical data is available).
5. Check gaskets match flanges and are
suitable for the service.
6. Check that the pipeline, upstream and
downstream, is correctly aligned.
7. if a Deflector cone is being used, fit it to
upstream side of valve with the cone nozzle
pointing downstream, prior to installation.
Metal (Chrome iron) cones must have
gaskets fitted between the cone and valve,
and between cone and flange. resilient
urethane cones do not require these
gaskets.
8. spread flanges to clear valve, check
flow arrow on side of valve is in the right
direction. (Valve seating face and gate are
downstream). lower valve into position.
insert gaskets, 1 each side.
9. insert flange bolts. On wafer valves, insert
bolts into the threaded bolt holes in the
chest of the valve first but do not tighten
until all bolts are fitted. tighten bolts in
a diagonal sequence (refer Fig. 2).
10. ensure bolts in the chest area of the valve
are not bottoming out in the blind holes.
11. Open and close valve to check it is operating
correctly.
12. after pipe line is pressurized, check for
flange leaks and for gland leaks, adjust as
necessary.
neither emerson, emerson automation solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product.
responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Keystone is a mark owned by one of the companies in the emerson automation solutions business unit of emerson electric Co. emerson automation solutions, emerson
and the emerson logo are trademarks and service marks of emerson electric Co. all other marks are the property of their respective owners.
the contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. all sales are governed by
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without
notice.
emerson.com/FinalControl
purge ports (wHere Fitted)
Optional stainless steel purge nozzles can be
fitted in lower part of body. if sedimentation
occurs preventing gate from closing fully, purge
with compressed air or water. alternatively,
connect permanent installation to purge ports
and purge periodically. Purge port hole is 3 mm
(⅛") BsPP.
gland adjustMent
the gland on new and repaired valves may
require final adjustment after installation and
pressurisation of the valve. if packing leaks,
tighten gland nuts equally until leaking ceases.
a 32 mm (1¼") aF spanner fits Dn 50 - 600
(nPs 2 - 24) valve size.
if gland leakage persists, check that pipeline
is not pressurized above rating of valve.
alternatively, packing may be damaged,
wrongly installed or have foreign matter caught
between gate and packing.
Disassemble, inspect and repair or replace
as necessary.
Caution
Do NOT over tighten gland packing as it will
cause excessive resistance to gate movement.
saFety
the gland on new and repaired valves may
require final adjustment after installation
and pressurisation of the valve.
actuated valves are generally operated from a
remote location, caution should be exercised if
working in close proximity to any moving parts.
note
to minimize risk to personnel, emerson recommend
the use of purpose built guards and shrouds. refer to
the emerson data sheet or consult factory for details.
Figure 2
1