The boilers are intended to be installed in ground premises with a possibility of easy
refueling with coal.
They are intended for heating in systems with local heat-supply, as well as for warming up
of household drinking water.
Model
MA18
GA 26
GA33
LB
SLB
The boilers consist of the following elements:
The main part the boiler is the heat exchanger. The heat exchanger represents a welded construction of
steel sheet material. In its lower part a combustion chamber is formed.
The ash-pan is set under the combustion chamber. The ash residue is gathered and allows simplified
operation when cleaning of the equipment.
The input orifice (nozzle) is located above and the output orifice (nozzles) - in the in the back part of
the boiler and represent two terminals with external thread G 1 "(G 1
which the boiler is connected to the heating system.
The chimney stack is located at the top of the boiler and used lead away the flue gases through a
chimney.
The steel heat exchanger is insulated with mineral insulation, which limits the heat loss to the
environment.
The external decorative side panels are made of steel sheet and are coloured powder coated.
The boilers PRITY LB PRITY SLB and have the possibility to work with wood pellets after
installation of the respective pellet burner on the door of the combustion chamber.
RESIDENTIAL BOILERS FOR SOLID FUEL
TECHNICAL DATA
Maximum heat
Max. pressure of
power, kW
19
28
36
44
36
Minimum draught,
the water, bar
1,5
1,5
1,5
2,5
2,5
Volume of the
Pa
water jacket, l
22
25
30
30
30
1/4
" for LB and SLB), through
35
62
70
84
64