In this case they have the following characteristics:
Necessary draught of the chimney, Pa
Water content, l
Temperature of the flue gases at nominal heat power, °C
Diameter of the chimney stack, mm
Nominal heat power, kW
Minimum heat power, kW
Efficiency, %
Average emission of CO, %
Average dust emission, mg/m3
Class boiler
Set range of temperature controller, °C
Type of the fuel – wooden pellets with humidity till 10%
The boiler is placed on a stable fireproof horizontal floor. To protect the floor, a stable fireproof
base can be used, which shall stick out before the boiler at least 50 cm in front and 30 cm at the side.
In the radiating area of the boiler, at a distance of 80 cm around it no objects burnable and
damageable by the radiated heat shall be there.
Before connecting the boiler to the chimney, consult a specialist.
The connecting elements (rosette and chimney) must be fixed tightly and firmly, so that they may
not get into in the passage section of the chimney. The smoking pipes shall have the same size as the
connecting pipe of the boiler.
It is advisable that the boiler work with a separate chimney. If other heating appliances are
connected to the same chimney, it must be calculated for that.
Fresh air must get in the boiler at least 4 m
necessary a flow from adjacent premises or outside air is ensured.
The burning process of the boiler must not feel shortage of air on the action of gravitational or
forced aspirations, since this is a prerequisite for insufficient combustion or returning of flue gases in
the premises.
It follows a connection of the water-hating pellet boiler to the heating installation through
suitable fittings and fixture according to the prepared beforehand thermo-technical project.
The requirements for installation of the pellet burner and the feeder screw
(auger) for fueling from a tank to the burner are given in its manual for
installation and operation.

INSTALLATION INSTRUCTIONS

3
/h for each kilowatt from its heat output. When
PRITY LB
30
84
309
150
40
15
80
0,32
58
1
30÷80
Wooden pellets with
humidity till 10%
PRITY SLB
30
64
300
150
33
15
82
0,32
56
1
30÷80
Wooden pellets with
humidity till 10%