Environmental Conditions; Mechanical Characteristics; Installation; Dimensions - Nera Evolution Series Technical Description

Multi service radio link system, 5 - 38 ghz
Table of Contents

Advertisement

4.2.7.

Environmental conditions

The equipment conforms to the environmental classes defined in ETS-300-019:
• Transportation:
• Storage:
• Use:
Indoor mounted units:
Outdoor mounted units: Standard temperature range: -33 ° C to +50 ° C.
4.3.

Mechanical Characteristics

4.3.1.

Installation

The equipment is very easy and quick to install. It is designed for stationary use in split mount
installations. IFU and ODU are interconnected with coaxial cable. One cable for each ODU is used. (i.e.
Two cables needed for HSB, 1+1 FD and 2+0 systems). The IFU can be installed as a stand-alone unit,
or it can be mounted in a standard 19" rack (Ref. IEC 297-2 and IEC 297-3), or in an ETSI standard
cabinet (Ref. ETSI EN 300 119). The ODU
to and including 1.8 m. Alternatively the ODU can be supplied with a mount for a vertical column (Ø=60-
115mm).
4.3.2.

Dimensions

2
IFU
1+0/1+1/HSB:
ODU 1+0,
6 - 11 GHz:
ODU 1+0,
13 - 38 GHz:
RF Coupler
6 - 11 GHz
13 - 38 GHz:
4.3.3.

Weights

IFU:
ODU 6 - 11 GHz:
ODU 13 - 38 GHz:
RF Coupler:
1
The ODUs in 6 GHz are pole mounted
2
The width and depth of the unit are exclusive flanges (mounting brackets) and table studs for free-standing mounting. Special
brackets for mounting into different cabinets are available
3
The 6 GHz RF-coupler has a shorter antenna insert
NGP\00329 Rev. C 23-06-2006
ETSI-EN-300-019-1-2, class 2.3, public transportation.
(temperature range: -40 ° C to +70 ° C).
ETSI-EN-300-019-1-1, class 1.2, weather protected,
not temperature-controlled storage locations.
(temperature range: -40 ° C to +70 ° C).
Temperature range: -5 ° C to +50 ° C.
According to ETSI-EN-300-019-1-3, class 3.2, partly temperature-
controlled locations.
For temperatures between +45 ° C and +50 ° C the relative humidity
must be between 5% and 40%.
According to ETSI-EN-300-019-1-4, class 4.1 , non weather
protected locations
For temperatures below 0 ° C the equipment must be switched on
for at least 10 minutes in order to operate according to the
specifications.
1
may be mounted directly to the antenna for antenna sizes up
444 mm (W) x 225 mm (D) x 44 mm (H), 17.5" x 8.9" x 1.73"
227 mm (W) x 140 mm (D) x 240 mm (H), 8.9" x 5.5" x 9.4"
206 mm (W) x 132 mm (D) x 210 mm (H), 8.1" x 5.2" x 8.4"
3
:
232 mm (W) x 102 mm (D) x 415 mm (H), 9.1" x 4.0" x 16.3"
220 mm (W) x 106 mm (D) x 374 mm (H), 8.7" x 4.2" x 14.7"
2.5 kg / 5.5 lbs
8.0 kg / 17.7 lbs
6.5 kg / 14.3 lbs
5 kg / 11 lbs
Evolution Series - XPAND
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution xpand

Table of Contents