Electrical Connections; Water Supply And Drain Connections - Hoshizaki DIM-30DE-1 Instruction Manual

Cube ice dispenser
Hide thumbs Also See for DIM-30DE-1:
Table of Contents

Advertisement

* Secure the ice dispenser to the wall by using
the braces (accessories) and mounting screws
(not supplied). Bend the braces according to
the installation condition.

6. ELECTRICAL CONNECTIONS

To prevent possible severe electrical shock to individuals or extensive damage to the unit,
the icemaker must be connected via the flexible supply cord supplied with the icemaker to an
appropriate outlet socket installed in accordance with local codes and regulations i.e. AS / NZS
3000.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* It is recommended that these appliances are connected to a separate 240VAC supply, protected by an appropriate circuit
breaker and Residual Current Device. Check the nameplate on the icemaker for the supply requirements.
* The main control box fuse is rated at 5A and should only be replaced by a qualified service engineer.
* The service of a licensed electrician may be required to ensure the installation is in accordance with the local codes and
regulations.
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live

7. WATER SUPPLY AND DRAIN CONNECTIONS

* The service of a licensed plumber may be required to ensure the installation is in accordance with the local codes and
regulations.
[Connection to the water supply]
* The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia and in
accordance with AS / NZS 3500.1 and AS / NZS 3500.2. This appliance incorporates backflow protection complying with AS /
NZS 3500.1. No further backflow protection is required for connection to the water supply.
* Icemaking water must be potable water. Where scaling can be caused by water quality, installation of an external filter or
softener is recommended. Contact your local water treatment professional or Hoshizaki service agent.
* Water supply pressure should be minimum 0.07 MPa (0.7 bar) and maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78
MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.
* Attach the angle end of the inlet hose to the
WARNING
THIS APPLIANCE MUST BE EARTHED
WARNING
Connect to potable cold water supply only.
water inlet fitting on the rear of the icemaker.
Rc1/2
Adjustable Leg
5
ENGLISH
Brace
Machine
Screw (M4)
Mounting Screw