Philio PAN05-1A User Manual

In wall single relay 1 way switch module

Advertisement

PAN05-1A/-2A/-3A
In Wall Single relay (1 way) switch
module
Fig 1. Assembling
This in-wall switch module is a transceiver which is a security enabled device which
P
based on Z-Wave Plus technology, and it is fully compatible with any Z-Wave
enabled network. Mini size design let the module can easily hide itself into the wall
box and that will be good for the house decoration. Since PAN05 supports Security
Command Class, it can learn with Secured controller. Its functionality and supported
command classes is identical when included as a secure and non-secure device.
There are many kind of application by using the module to switch Load On and Off,
one main application is the light control. If connect the COM terminal directly to AC
Line terminal, the new smart relay calibration technology can reduce the inrush
current caused by the load and let the module work perfectly with many kind of light
like incandescent, fluorescent and LED light. This module can also connect to
alternative power supply like DC 12V to switch on/off 12V MR-16 light as follow
picture.
TM
Adding to Z-Wave
Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carries out inclusion, exclusion, reset or association.
When first power applied, its LED flashes on and off alternately and repeatedly at 0.5
second intervals. It implies that it has not been assigned a node ID and start auto
inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not
have Node ID and just connect the switch to main power.
1
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAN05-1A and is the answer not in the manual?

Questions and answers

Summary of Contents for Philio PAN05-1A

  • Page 1 PAN05-1A/-2A/-3A In Wall Single relay (1 way) switch based on Z-Wave Plus technology, and it is fully compatible with any Z-Wave module enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. Since PAN05 supports Security Command Class, it can learn with Secured controller.
  • Page 2: Led Indication

    The PAN05 is an always listening Association Z-Wave device, so associations Note: Auto inclusion timeout is 2 minute during which the node information of may be added or removed by a controller at any time. explorer frame will be emitted once every several seconds. Unlike “inclusion” function Or If your controller requires to have the PAN05 send a 'node information as shown in the table below, the execution of auto inclusion is free from pressing the...
  • Page 3: Choosing A Suitable Location

    Choosing a Suitable Location Programming 1. Basic Command Class / Binary Switch Command Class 1. Do not locate the Switch facing direct sunlight, humid or dusty place. The Switch will respond to BASIC and BINARY commands that are part of the 2.
  • Page 4 2-1 Auto report to Grouping 1 (Maximum Node 1) mode 2:Show night mode 3 : One flash 2-1-1 On/Off Event Report mode When “on” or “off” state has been changed (ex. Press S1 S2 or include on/off Auto off 0-0x7F 0:Disable auto Second button), it will send Binary Switch Report to the nodes of Group1.
  • Page 5: Troubleshooting

    3-3 Manual On/Off Mode 5. Command Classes The On/Off function of S1、S2 and learn switch can be disabled or enabled by this The Switch supports Command Classes including… parameter, default value is Enable. But the learning operation won’t be affected. * COMMAND_CLASS_ZWAVEPLUS_INFO_V2 3-4 LED indication Mode * COMMAND_CLASS_VERSION_V2...
  • Page 6: Specification

    They can take this product for environmental safe recycling. (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including Company of License Holder:Philio Technology Corporation interference that may cause undesired operation. Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New FCC Caution: Any changes or modifications not expressly approved by Taipei City 24257,Taiwan(R.O.C)

This manual is also suitable for:

Pan05-2aPan05-3a

Table of Contents