During Burst Mode Operation - Infineon CoolSET ICE2QR 80 Series Design Manual

Quasi resonance
Table of Contents

Advertisement

The feedback voltage is lower than the threshold of V
across the shunt resistor is 0.17V;
The up/down counter has its maximal value of 7;
The two above conditions have to been fulfilled for a certain blanking time duration t
Once all of these conditions are fulfilled, the active burst mode flip-flop is set and the CoolSET enters burst
mode operation and the gate will be turned off until V
to enter the active burst mode depends on the up counting time and the 30ms extra blanking time.
For example. If before the load change, current up/down counter value is 3, then the total blanking time will
be:
(7-3) x 48ms + 30ms = 222ms.
This multi-conditional determination for entering active burst mode operation prevents mistriggering of
entering active burst mode operation, so that the CoolSET enters active burst mode operation only when the
output power is really low during the preset blanking time.
4.4.2

During Burst Mode Operation

After entering the Active Burst Mode the feedback voltage rises as V
PWM section. One comparator observes the feedback signal if the voltage level V
that case the internal circuit is again activated by the internal bias to start with switching.
Turn-on of the power MOSFET is triggered by the timer. The PWM generator for burst mode operation
composes of a timer with a fixed frequency of 52 kHz, typically, and an analog comparator. Turn-off is
resulted by comparison of the voltage signal V
shunt resistor V
is 0.34V, accordingly. A turn-off can also be triggered by the maximal duty ratio CoolSET
csB
which sets the maximal duty ratio to 50%. In operation, the output flip-flop will be reset by one of these
signals which come first.
Figure 7 Signals in active burst mode
Design Guide
T
7
counter
totalblank
ing
with an internal threshold, by which the voltage across the
1
V
Entering
FB
Active Burst
Mode
V
FBLB
V
FBBOn
V
FBBOff
V
FBEB
th
time to 7
zero and
blanking Window (t
V
CS
Current limit level
1.0V
during Active Burst
Mode
V
CSB
V
VCC
V
VCCoff
V
O
Max. Ripple < 1%
12
Quasi-resonant CoolSET design guide
(1.25V). Accordingly, the peak voltage
EB
increase to on threshold V
FB
_
value
48
ms
30
starts to decrease due to the inactive
O
Leaving
Active Burst
Mode
t
)
BEB
t
t
t
ICE2QRxx65/80x
(30ms)
BEB
. The total blanking time
BH
ms
(3.6V) is exceeded. In
BH
8 August 2011

Advertisement

Table of Contents
loading

This manual is also suitable for:

Coolset ice2qr 65 series

Table of Contents