Reassembly; Disposal At End Of Useful Life; Telephone Assistance - Emerson Penberthy Installation, Operation And Maintenance Manual

Flat glass gage scales

Advertisement

Penberthy FlaT glass gagE scalEs
InstallatIon, operatIon and maIntenance InstructIons
CautIOn
If gage scale mounting brackets (73) are to be
removed from the flat glass gage, the gage
must first be relieved of all pressure or vacuum,
been allowed to reach ambient temperature and
drained or purged of all fluids.

7.2 reassembly

Refer to the exploded parts drawing in
section 10 for additional reference during
disassembly and reassembly of the gage scale.
1. If mounting brackets (73) were removed
during disassembly, place brackets on the
bolts with the bracket inset away from the
flat glass gage, thread nuts on finger tight.
2. Place the gage scale into the insets of the
mounting brackets (73). The '0' reading of
the gage scale should be aligned with the
bottom of the vision slot in the flat glass
gage.
3. Hold the scale firmly in place in the bracket
(73) insets, tighten the set screws (100)
using a hex wrench.
4. If mounting brackets (73) were removed
during disassembly, using a torque wrench,
tighten all gage nuts to the proper torque
value as specified in the flat glass gage
Installation, Operation and Maintenance
Instructions provided.
WarnIng
Failure to comply with the proper torquing
sequence or force value can lead to leakage,
gasket blow-out or glass breakage resulting in
gage failure, serious personal injury or property
damage.
note: refer to section 5 Operation when
returning to service.

8 dIsPOsal at end OF useFul lIFe

Penberthy flat glass gage scales are used in
a variety of fluid applications. By following the
appropriate federal and industry regulations,
the user must determine the extent of
preparation and treatment the gage scale must
incur before its disposal. a Material safety Data
sheet (MsDs) may be required before disposal
services accept certain components.
Metal, glass and polymers should be recycled
whenever possible. Refer to order and the
applicable technical data sheet for materials
of construction.

9 telePhOne assIstanCe

If you are having difficulty with your flat glass
gage scale, contact your local Penberthy
distributor. You may also contact the factory
direct at (956) 430-2500 and ask for an
applications engineer. so that we may assist
you more effectively, please have as much of
the following information available as possible
when you call:
∙ Model #
∙ Name of the company from whom you
purchased the Penberthy flat glass gage
scale
∙ Invoice # and date
∙ Process conditions (pressure, flow rates,
tank shape, etc)
∙ a brief description of the problem
∙ Trouble shooting procedures that failed
If attempts to solve your problem fail, you may
request to return your gagecock to the factory
for intensive testing. You must obtain a Return
authorization (R.a.) number from Emerson
before returning anything. Failure to do so will
result in the unit being returned to you without
being tested, freight collect. To obtain an R.a.
number, the following information (in addition
to that above) is needed:
∙ Reason for return
∙ Person to contact at your company
∙ 'ship-to' address
There is a minimum charge for evaluation
of non-warranty units. You will be contacted
before any repairs are initiated should the cost
exceed the minimum charge. If you return a
unit under warranty, but it is not defective, the
minimum charge will apply.