Download Print this page

Sealey WPD235A.V2 Manual page 3

Submersible dirty water pumps - automatic

Advertisement

that the pump and discharge are working correctly.
4.4.
The water into which the pump is placed will act as the motor cooling agent. For this reason the pump must remain submerged at all
times. Should the pump have to be used in shallow water DO NOT operate for more than 10 minutes. Failure to follow this rule will
damage the unit and will invalidate your warranty.
NOTE:
See fig.2 to determine minimum clearance required if using pump in a restricted area i.e. well, etc.
5. MAINTENANCE
WARNING! With the exception listed below, all pump, float and electrical cable service maintenance and repair must only be
undertaken by an authorised service agent. failure to observe this rule may be dangerous and will invalidate your warranty.
WARNING! Ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.
5.1.
Keep all parts of the pump clean. Rinse, drain and allow to dry before storing pump.
5.2.
Regularly check the water inlet on the base of the pump to ensure there are no blockages. To access the impeller carefully undo the
base hex headed screws and remove base. Clean impeller and replace base ensuring that the o ring is correctly located.
DO NOT dismantle any other part of the unit.
8
TROUBLESHOOTING
a. Motor operates but
there is no suction.
b. Reduced water
volume for level
of water
c. The pump will not
start or suddenly
stops during
operation.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey limited
1. Water level below min suction depth.
2. Air bubbles in pump accumulated during submersion,
or float is incorrectly positioned so pump does not stop
at minimum level and sucks in air.
3. Clogged intake filter or discharge pipe.
1. discharge pipe bent, or pinched.
2. discharge pipe too narrow.
3. Pump partially blocked.
1. no electrical power.
2. Float not working.
3. Impeller is jammed.
01284 703534
Original Language Version
1. Stop the pump.
2. Release air by inclining the pump and
re-immersing it in water.
3. Remove blockage, and clean the unit.
1. Straighten pipe.
2. Use wider diameter pipe.
3. Clean pump.
1. Check cable, plug and fuse.
2. Contact authorised service agent.
3. Clean the pump.
sales@sealey.co.uk
WPD235A.V2 WPS225A.V2 Issue 3 (HF) 10/08/18
www.sealey.co.uk

Advertisement

loading

This manual is also suitable for:

Wps225a.v2