Download Print this page

Important Safety Instructions; Operation; Non-Rechargeable Battery; Charging Indicators - Easylife Battery Wizard EL6749 Instruction Manual

Advertisement

Genius blue is
C90, M7, Y0, K0
Genius green is
C90, M7, Y0, K0
PANTONE 072 C
PANTONE 123 C
Dear Customer,
Thank you for purchasing the Battery Wizard.
Now ordinary batteries are rechargeable - with Battery Wizard
There used to be two sorts of batteries - those you could recharge and those you couldn't.
Battery Wizard has changed all that. Yes, it lets you recharge rechargeable batteries, but
also enables you to charge good quality ordinary alkaline batteries up to 10 times. So battery
wizardry saves you £££s as well as being very eco-friendly. It automatically checks the
type and size of battery before charging and rejects faulty batteries, thanks to the built-in
microprocessor it. It even has 6 LED lights that indicate battery status. Highly effective, the
Battery Wizard puts new life into AA, AAA, C, D, 9V and N across alkaline, rechargeable
Ni-Cad, Ni-Mh, high power and zinc carbon types. Powered by the mains via an adaptor
(supplied), it measures 29.5x18x6cm .

IMPORTANT SAFETY INSTRUCTIONS

The most suitable environment for the charger to work in is ambient temperature: 0-25, ambient
humidity <80%. (Do not operate the charger in high ambient temperature or high humidity). The
temperature of batteries should not exceed 45̊ during charging. (Exceeding these conditions could
result in a shortened battery life, and or exploding batteries.)
Make sure that the charger lid is in the closed position during the charging sequences.
Make sure the adaptor is compatible with UK voltage.
If the adaptor is damaged, please do not use the product and contact our customer services team
Keep children away from the adaptor/charger when in use.
Keep away from water, and sources of heat when the charger is working.
Remove the plug from the wall socket after charging is complete and before removing the batteries
from the charger.
Remove batteries as soon as possible after charging is complete.
Do not charge Li-Ion batteries.
Never leave unattended
There are no user serviceable parts, please return to your supplier if a fault occurs.
WARNING
Rechargeable battery - Charge NO more than
4 hours after the light flashes green. Flashing
green indicates battery is fully charged. Note:
Lights are not meant to stop.
Non-Rechargeable - Remove batteries
immediately after light flashes green.
Li-Ion battery – Do not charge
Suitable Battery Type:
Do not recharge any Li-Ion batteries.
Only recharge; NiCd, Ni-Mh, high-power, 9V, and
zinc carbon batteries.
Paper weight 60gsm
9V
1.2V
1.2V
1.2V
1.2V
12V
Rechargeable
battery only
e v e ry d ay s o l u t i o n s
Est. 1992
Rechargeable battery
The four 1.2V positions will charge different sizes of 1.2V rechargeable batteries.
They are can be NI-MH or rechargeable alkaline batteries.
The 12V position will charge 12V rechargeable batteries only.
The 9V positions will charge 9V rechargeable batteries only.

Non-rechargeable battery

Note: The four 1.2V positions of the charger can also charge disposable battery (non-rechargeable type) such
as alkaline, high power battery for emergency use. However, the charging effect is limited, so the user should
not attempt to charge this type of battery frequently.
Good brands (eg. Duracell) can be recharged a maximum 10 times.
The 12V position will charge 12V rechargeable batteries only.
The 9V positions will charge 9V rechargeable batteries only.

OPERATION

1.
Insert battery into different position and make sure the polarity is right by following the markings on the
plastic housing of the compartment.
2.
Attach the adaptor to the jack in the back of the product and plug into the mains power.
3.
Adjust the position of the battery in the slot so the negative side of battery is touching the metal contact -
refer to picture

Charging Indicators:

1.
When connected to the mains and no battery is fitted, the indicator lamps of all six positions will flash
green.
2.
When an empty battery is inserted in any one of the positions, the corresponding indicator lamps will flash
red.
3.
When the battery is close to fully charged, the corresponding indicator lamp of the position will flash
between green and red.
The duration of this state will vary for different battery capacity and type
When rechargeable batteries are fully charged, the corresponding indicator lamps will flash green.
Note: When the indicator lamp for the position turns from red to green and ambient temperature <25
charging for 2-4 hours to make sure batteries are fully charged. However do not exceed a maximum of 4
hours. (Batteries will not be damaged if charging continues after the indicator lamp turns from red to green as
long as extra charging does not exceed 4 hours).
The alarm will sound if there is an error such as faulty battery, short circuit or if batteries are incorrectly inserted.
When non-rechargeable batteries are fully charged, the corresponding indicator lamps will flash green.
Remove the batteries immediately after indicators flash green.
The alarm will sound if there is an error such as faulty battery, short circuit or if batteries are incorrectly inserted.
Position Protection by alarm sound
Each position (channel) has a built in protection, when problems such as short circuit, reverse polarity or
damaged batteries are fitted, the charger will automatically detect and identify that a problem exists. When any
one position has a problem, an alarm will sound, warning the user to check the battery or battery placement for
possible issues, at the same time, the current of all positions except the 9V and 12V will be cut off. Once the
cause of the problem has been eliminated (damaged batteries are removed or batteries are properly positioned
into the charger), the alarm will stop and the four 1.2V positions will resume original charging state.
Support Line: 0303 031 0777
For more innovative products from Easylife please visit:
www.easylifegroup.com
continue
o

Advertisement

loading