Note 1:The test mode and recording of this set are controlled by a personal computer, thus requiring the set to be connected to the PC.
Prepare the personal computer in which necessary software is already installed.
• Attached software "OpenMG Jukebox" (necessary for recording (check in, check out)) (Part No. : 4-237-880-01)
• Software for test mode "TestMode_S.exe" ("TestMode_S.exe" and essential files "data_files.csv", "Net MDUSB.dil" are distributed to-
gether with the Service Manual. For the test mode, copy these three files in the same folder beforehand)
Note 2:In the operation in the test mode, the operational description requiring "click
("xxx" indicates the button name)
Iop DATA RECORDING AND DISPLAY WHEN OPTICAL PICK-UP AND NON-VOLATILE MEMORY (IC195 OF
BD BOARD) ARE REPLACED
The Iop value labeled on the optical pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need
to look at the value on the optical pick-up label. When replacing the optical pick-up or non-volatile memory (IC195 of BD board), record
the Iop value on the optical pick-up according to the following procedure.
Record Procedure:
[
]
1. Press the
B/>
button and
cable must be disconnected)
2. Connect the set to the PC with the attached USB cable.
3. Start up the software for test mode.
[TEST MODE]
4. Click the
.
[JOG UP]
[JOG DOWN]
5. Click the
or
[JOG UP]
[JOG DOWN]
6. Click the
or
7. The display becomes "Ref=@@@.@" (@ is an arbitrary number) and the numbers which can be changed will blink.
8. Input the Iop value written on the optical pick-up label.
To select the number : Click the
To select the digit
: Click the
[ENTER/YES]
9. When the
10. As the adjustment results are recorded for the 6 value. Leave it as it is and click the
11. "Complete!" will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become "Iop
Write (C05)".
12. Quit the software for test mode after the
Note: When retrying this operation start from step1.
Display Procedure:
[
]
1. Press the
B/>
button and
cable must be disconnected)
2. Connect the set to the PC with the attached USB cable.
3. Start up the software for test mode.
[TEST MODE]
4. Click the
.
[JOG UP]
[JOG DOWN]
5. Click the
or
[JOG UP]
[JOG DOWN]
6. Click the
or
7. "@@.@/##.#" is displayed and the recorded contents are displayed.
@@.@ : indicates the Iop value on the optical pick-up label.
##.#
: indicates the Iop value after adjustment
[PUSH]
8. To end, click the
9. Quit the software for test mode after the
Note: When retrying this operation start from step1.
[
]
x/Z
button until the NetMD indicator turns off (for more than 3 seconds). (During this step, the USB
to display "[Service]", and click the
to display "Iop Write" (C05), and click the
[JOG UP]
[JOG DOWN]
or
[PUSH]
.
is clicked, the display becomes "Measu=@@@.@" (@ is an arbitrary number).
[REPEAT]
clicked.
[
]
x/Z
button until the NetMD indicator turns off (for more than 3 seconds). (During this step, the USB
to display "[Service]", and click the
to display "Iop Read" (C26), and click the
[MENU/NO]
and
to display "Iop Read" (C26).
[REPEAT]
clicked.
[xxx]
" means that you have to click the button on the screen.
[ENTER/YES]
[ENTER/YES]
.
[PUSH]
[ENTER/YES]
[ENTER/YES]
MDS-NT1
.
.
.
.
.
9