Digital wired conference system, gooseneck microphone with led ring, discussion unit, interpretation unit, control unit, integration unit, link extender, voting unit, ir discussion unit, hybrid control unit, hybrid control unit dante-enabled, ir transmitt (85 pages)
Hybrid infrared conference system gooseneck microphone with led ring ir discussion unit hybrid control unit hybrid control unit (dante-enabled) ir transmitter unit ir distributor charger (22 pages)
Summary of Contents for Audio Technica ATUC-50
Page 1
Instruction Manual - Web Remote Edition - ATUC-50 Digital Wired Conference System Gooseneck Microphone with LED Ring ATUC-M43H/58H/M32L Discussion Unit ATUC-50DU Interpretation Unit ATUC-50INT Control Unit ATUC-50CU Integration Unit ATUC-50IU Link Extender ATLK-EXT165 ATUC-IR Hybrid Infrared Conference System Gooseneck Microphone with LED Ring...
Table of Contents Introduction .......... 3 About this manual ..........3 About the information in this manual ........3 About the configuration of this manual ........3 About registered trademarks and copyrights ......3 Preparing to use Web Remote ....... 4 W hat is Web Remote? ...............
In this manual, the TM and mark may not be specified. Web Remote. Refer to the “Main Unit Edition” for information about the digital wired conference system ATUC-50 and the hybrid infrared system ATUC-IR products. Device names The device names are abbreviated as follows.
Preparing to use Web Remote For iOS users: Search from App Store and install “Locate”. What is Web Remote? Proceed to step 4. Web Remote is a web application to control this system. For Android users: Using Web Remote enables you to remotely perform the following operations from a computer or mobile device (hereinafter, control Search from Google Play and install “Locate”.
Configuring and Operating Conferences Using the Web Remote Control Function About Web Remote Furthermore, you can configure DU detail settings, such as speaker settings and LED color, for each DU and the interpretation settings for each INT. ➤ [Presets] ( page 30) Overall structure of Web Remote Allows you to save settings configured from [Install Settings] as...
CU to the control device using an ➤ Ethernet cable ( ATUC-50/ATUC-IR Instruction Manual (Main Unit Edition)). Header always displayed on the screen. (1) From the CU Set Menu → System Info → IP Address , check ➤...
Configuring detailed system settings Change the settings as necessary, then click [Apply]. ([Settings & Maintenance]) From this menu, detailed system settings can be configured. Utilities for troubleshooting and maintenance are also available. How to operate the [Settings & Maintenance] menu On the Web Remote Home screen, click [Settings &...
Menu item ① ([System Settings]) The setting values and default setting of each item which you can set from [System Settings] are as follows. is the name of an item displayed on the CU display. Items with are included in the preset settings. General Settings ([General]) Item name Description and setting values (default settings are shown in bold)
Page 9
Do the secondary IP settings. The settings for the various items are the same as for primary. - - IP Settings (Secondary) ✔ Only displayed when the network configuration [Mode] is set to [Redundant Audio]. IP Control & Web Remote Port IP Settings is displayed when the Dante PCB Assy is not connected.
Page 10
End Date & Time Set the end date and time for daylight saving time. DST End Date 1/1 - 12/31 (10/30) ✔ ✔ ✔ DST End Time 0:00 - 23:00 (2:00) Infrared Settings ([Infrared]) Item name Description and setting values (default settings are shown in bold ) 50CU IRCU IRCUDAN...
Page 11
- - Logging Yes, No ✔ - - System Info Yes, No ✔ Operator 1 Access Settings Set a name for the rights of Operator 1. - Name ✔ ✔ Operator 1 Enable/disable login password requirement for Operator 1. Login Password -...
Page 12
The following operations can be performed from [System Settings]. Item name Description and operation procedure 50CU IRCU IRCUDAN Updates the CU firmware. Preset Monthly Sales Meeting ATUC-50 Settings & Maintenance ATUC-50CU Firmware Update System Settings Serial Number Device Name Firmware Version General ①...
Page 13
Updates the IRCU firmware (same as ATUC-50CU firmware update). ① ③ ② ATUC-IR Control Unit Firmware - ✔ ✔ Update ① Check the [Serial Number], [Device Name], and the current [Firmware Version] on the screen to be sure that the displayed CU is the one you want to update.
Page 14
Updates the DU firmware. ① ③ ② ATUC-50DU Firmware Update ✔ ✔ ✔ ① Click the checkbox next to the [Serial Number], [Delegate Name], and the current [Firmware Version] of each DU you want to update. W hen you want to select all DUs, click [All] on the upper left of the DU Firmware Update section on the screen.
Page 15
Updates the INT firmware. ① ③ ② ATUC-50INT Unit Firmware Update ✔ ✔ ✔ ① Click the checkbox next to the [Serial Number], [Delegate Name], and the current [Firmware Version] of each INT you want to update. W hen you want to select all INTs, click [All] on the upper left of the INT Unit Firmware Update section on the screen.
Set whether to mix the voice being input with Language 2. ✔ ✔ ✔ (Only Mic/Line 2) On, Off Configure the external input settings for ATUC-50, such as audio type and level. Type Set the nominal level of the external input. - -...
Page 17
Set whether to mix the voice being input with Language 2. - Mix to Language 2 ✔ ✔ On, Off Configure the level of the return input for ATUC-50 and the EQ pattern for the Return 1-2 return input. Set the nominal level of the return inputs. - -...
Feedback Suppression Settings Detects feedback and displays the frequency with the notch filter applied. W hen [Static] is set to [Off ], the frequency dynamically changes according to Frequency feedback detected. ✔ ✔ ✔ * W hen [Static] is set to [On], the [Frequency] value is included in the preset setting as the frequency of the static filter.
Page 19
Reset All Restores all bands to the factory default settings. ✔ ✔ ✔ Configure the DYN (dynamics) settings. Ticking the checkbox sets DYN of Output 1 to [On] and makes the setting button ( ) selectable. Click the (Output 1 only) setting button ( ) to open the [Dynamics Settings] screen and then configure various settings as follows.
Page 20
W hen [Conference Mode] is set to [Request Talk] or [Full Remote], this item switches to [Mic ON Trigger for Priority], which is the setting for priority Mic ON Trigger / Mic ON Trigger DUs. for Priority(*1) ATUC-50: All Voice , All Button (Individual*) ✔ ✔ ✔ MicON Trigger...
Page 21
It is possible to replay any audio file, such as a buzzer or chime that has been saved to a USB device (mass storage device). SFX 1-3 Setting A maximum of 3 audio files can be registered and assigned to the 3 buttons ➤...
Page 22
ATUC-IRDU Settings Set the color of IRDU Multifunction LEDs for each function; Talk ON, Multifunction LED Queuing, Cut/Mute, and Permit Next. Select and set the color of the Multifunction LED when someone is talking. Talk ON 9 colors ( Red ) Select and set the color of the Talk LED when waiting to talk.
Page 23
*1: About setting changes Settings can be changed when all DU/IUs are in the Talk OFF state. *2: About the priority setting Priority DU/IU(s) are given authorization to do the following: • Talk anytime • Cut short or temporarily mute all other attendees simultaneously It is assumed that the priority setting is enabled on DU/IUs that are used by people in charge of the proceedings of a conference, such as a chairman or company directors who are permitted to talk anytime.
Page 24
DU/IU Detail Settings ([DU/IU Detail Settings]) Item name Description and setting values (default settings are shown in bold) IRDU 50DU 50IU Microphone Configure microphone-related settings. Level Displays the level with a level meter. ✔ ✔ ✔ Set the microphone input gain. Input Gain ✔...
Page 25
➤ Priority Configure the priority ( page 23) settings. Enable/disable the priority setting. The maximum number of DUs that can be designated as priority DU is 1 unit less than the maximum number of DUs Enabled ✔ ✔ ✔ ➤ (speakers) that can talk at the same time ( page 20).
Page 26
GPO Pin Settings (This is a setting item only for IUs.) Set the function to assign GPO port 0 to port 7. GPO x (x is any port number 0 to 7): use as a general purpose output pin Self-Mute Indicator: Indicates when self-muted Lit: Self-muted Cut/Mute Indicator: Indicates when a mic is disconnected or muted Lit: Muted...
Page 27
Interpretation Settings ([Interpretation Settings]) Item name Description and setting values (default settings are shown in bold ) 50CU IRCU IRCUDAN Interpretation Settings Set the interpretation mode. Interpretation Mode 2 Languages, 3 Languages ✔ ✔ ✔ Automatically toggles the voice on the floor with the voice of the interpreter. W hen [On] is set, for example, the voice on the floor is automatically output to language group 1 by putting INTs that are outputting an interpreter’s voice to Easy Mode...
Page 28
*1: About Operations of the INT Unit Settings ② ① Click ① the INT(s) for which you want to change the settings. A check mark appears in the checkbox. You can also select multiple INTs and simultaneously change settings of the selected INTs. Click ②...
Page 29
Off, 15 min, 30 min, 1 hour, 2 hours Specify prefix for recorded audio files. Rec Filename Prefix ➤ Up to 30 characters can be used. (Some characters cannot be used ( ATUC-50/ATUC-IR Filename Prefix Instruction Manual (Main Unit Edition)). The default setting is atuc-50.)
Click the operation you want to perform. The selected operation will be executed. Recall ( Recall Presets ) (ATUC-50 only): Sets the selected preset as the current setting. Save ( Save Presets ) (ATUC-50 only): Saves the current setting to the selected preset number.
Log management ([Logging]) Displaying the system information ([System Info]) Configure the system log settings. You can also download the log file. Display the system information such as the firmware version, various network setting statuses, and unit serial numbers. Enabled ( Logging ): Set whether to save the system log.
Preparing for conferences ([Setup Conference]) To handle many different types of conferences using a conference system, it is recommended to preset multiple types of conference settings. Basic conference preparation can be carried out simply by recalling the preset that best suits an upcoming conference. Up to 8 conference settings can be preset.
From the drop-down list ② , click [Edit Detail 3 Adjusting the DU/IU settings ([DU/IU Settings]. Settings], [DU/IU Detail Settings]) Displays the [DU/IU Detail Settings] screen and enables you to configure DU/IU detail settings. Configure DU/IU settings and DU/IU detail settings. Configure DU/IU detail settings and click [Apply] Change the settings as necessary.
Operating and controlling ⑦ Set MIC/LINE to on or off. ⑧ Perform the recording operations. See “Recording operations” conferences ([Start Conference]) ➤ page 35). ⑨ Click repeatedly to adjust the volume level. Click the up/down buttons to adjust the volume level for OUTPUT 1. The [Start Conference] screen is displayed by clicking [Start ⑩...
Recording operations: ⑦ These are SFX operation buttons. Audio files set from ➤ [Conference Settings] are played ( page 32). Pressing an SFX Recording operations such as starting and stopping recording can be button plays the corresponding audio file. Click the button again performed either on the [Conference Manager] screen or on the ➤...
[Settings & Maintenance] → [System Settings] → [Utilities] [Settings & Maintenance] → [System Info] Symptom Cause/Solution Page ATUC-50/ ATUC-IR Check the connections of units including the CU and the control device such as a Instruction “Locate” does not recognize the CU computer.
Error messages • Error messages displayed on the Web Remote screen and CU displays are as follows. • The states of the CU LED error indicators are described together with the CU display error messages. • If the same error persists even after the following remedies are taken, or when the unit(s) requires repair or parts replacement, contact our sales representative.
Page 38
CU display Web Remote State/remedies (LED indicators) USB Access Error USB Access Err An error occurred when accessing the USB device (mass storage device). • Check that the USB device (mass storage device) has no problems. • Check that the same error does not occur with another USB device (mass storage device).
Page 39
CU display Web Remote State/remedies (LED indicators) Failed. Please turn power OFF. IU FW Update Err An error occurred during the IU firmware update. Please Turn Pwr OFF • Turn off the power and restart the CU. (W hen the update cannot be performed for the 1st IU, or an error occurs during the update process and the update cannot be continued.) Completed except serial Part of DU Failed...
Page 40
CU display Web Remote State/remedies (LED indicators) Number of IRDU exceeds Pst Recall Err The preset file cannot be read. The number in [Number of Open Mics] available IR Bands exceeds the number of [IRDU Band] that are enabled. • Set [Limit NOM to Enabled IR Bands] in [Infrared Settings] to [Off ]. Dante Communication Error Dante Comm Err A communication error occurred with the Dante board.
Need help?
Do you have a question about the ATUC-50 and is the answer not in the manual?
Questions and answers