UL Compliance Notes:
1). For UL1076 Proprietary Burglar Alarm Systems and Non-Stand Alone UL294 Access Control System (central monitoring
employed) installations, Altronix AL600ULX power supply must be used for system battery supervision function.
2). When using Altronix AL600ULX power supply, the installer will need to provide a remote input to the 8DC to monitor AC power
loss and battery supervision conditions as indicated below:
Altronix AL600ULX
Power Supply
DB/DBU Location
C
+
AC Fail
Monitoring
-
NO
Relay
NC
+
10K Ohm
C
-
Battery
NO
Monitoring
Relay
NC
10K Ohm
12 VDC Out
+
-
7000-0126
Black
Black
Black
12 VDC to power Local
Red
boards & devices
3). For UL294 Stand-Alone Installations, the MN-TRANS-150-UL and MN-PSU-6A can be employed.
9600-0422
. M2150 8DC Installation Instructions,
Issue 1.5 11th July 2011. © G4S Technology
2011. G4S Technology Limited cannot be held liable for technical and editorial omissions or errors
made herein; nor for incidental or consequential damages resulting from the furnishing,
performance or use of this material. All trademarks acknowledged.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference. In which case, the user will be required to correct the interference at his own expense.
I/O Board at
Program Monitor Point 1 as 3
State N.C., and program the
Monitor
Monitor Point Message to read
Point 1
"AC Power Fail, (Add Board
Description)"
Monitor
Program Monitor Point 2 as 3
Point 2
State N.C., and Alarm Message
should read "Battery Trouble,
(Add Board Description)"
-
Cabinet
AC Power /
Tamper Board
+
Specifications
Readers: 8 max.
Quiescent supply input: 100mA @11.7 to 12.7Vdc (excludes
readers and optional modules, with no relays energized).
Maximum supply input: 590mA @11.7 to 12.7Vdc (all modules
fitted, all board & module relays energized, excluding readers).
Each relay on the 8DC consumes 20mA when energized.
Operating Range: 14 to 131°F (-10 to 55°C) max. Humidity 15 to
90% non-condensing; indoor use only.
Compliance: EN50133, 1999/5/EC, UL 294 Access Control &
UL1076 Proprietary Burglar Alarm Systems.
M2150 8DC Installation Instructions
The 8DC is used to expand a database unit, by enabling direct connection of eight extra 20mA or Wiegand readers. Additional monitor
points and auxiliary outputs are available by fitting an optional I/O Module (the module type determines the number of available monitor
points and auxiliary outputs).
Note:
For additional information regarding the
installation, configuration and proper use of this
product:
SMS User Guide, P/N 9600-0429
M2150 Access Control Design Guide, P/N
9600-0420
M2150 Intrusion Guide, P/N 9600-0540.
M2150 UL1076 Compliance Manual, P/N 9600-
0449.
Some devices described in these instructions
may not be applicable for sites requiring UL
compliance. Please refer to the Access Control
Design Guide for details of the controllers,
modules and features that have been UL tested
for use with this device.
Mounting the Optional Modules
1
Note: For information on mounting the 8DC into the cabinet, refer to the appropriate cabinet installation instructions.
8DC
Replacement Parts:
Use only replacement parts provided by the manufacturer:
F1, P/N R-0811-6301
OPTIONAL
I/O MODULE
For connection details, see
the appropriate I/O Module
Installation Instructions
For an AC8/4 I/O Module,
inputs are numbered 1 to 8,
and outputs are numbered 1
to 4. For an OC4/8, inputs are
numbered 1 to 4, and outputs
are numbered 1 to 8.
WIM-8 MODULE
(required if Wiegand
readers are used)

Advertisement

loading

Summary of Contents for G4S M2150 8DC

  • Page 1 Issue 1.5 11th July 2011. © G4S Technology Readers: 8 max. 2011. G4S Technology Limited cannot be held liable for technical and editorial omissions or errors made herein; nor for incidental or consequential damages resulting from the furnishing, Quiescent supply input: 100mA @11.7 to 12.7Vdc (excludes performance or use of this material.