Summary of Contents for Bardiani Giotto-Top

  • Page 1 USE AND MAINTENANCE INSTRUCTIONS Giotto-Top ® GB-IST-GIOT-0112...
  • Page 2: Table Of Contents

    The data and the information supplied in this manual are subject to modifications or updates without written notice or other obligations for the manufacturer. (GB-IST-GIOT-0112) 2/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 3: Symbols Used

    NEVER remove a valve from a hose, or disassemble it, while the valve or the hose are pressurized. We decline all forms of responsibility for incorrect installation, use and maintenance! (GB-IST-GIOT-0112) 3/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 4: Structure And Functions Of Giotto Top

    • AS-i card: the LEDs indicate the status of the corresponding solenoid valve. (GB-IST-GIOT-0112) 4/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 5: Technical Data

    24 Vdc. Class 2, 4, 3 pursuant Air supply to ISO 8573-1 Working temperature -10...+50°C (GB-IST-GIOT-0112) 5/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 6 Technical data of the Inductive sensor Electrical power supply 24 Vdc For further information concerning the component, please consult the relevant manuals. (GB-IST-GIOT-0112) 6/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 7: Installation

    Always MAKE SURE the electrical and pneumatic connections are NOT activated whilst working on Giotto Top and that the power supply voltage ® is always and only 24 Vdc. (GB-IST-GIOT-0112) 7/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 8: Pneumatic Connections

    ® Select the appropriate length of the hoses so that Giotto Top can be removed by ® unscrewing the anchoring screws. (GB-IST-GIOT-0112) 8/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 9 B925 Valve open “AIR OUT 1” Upper seat flushing “AIR OUT 2” Lower seat flushing “AIT OUT 3” (GB-IST-GIOT-0112) 9/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 10: Disassembling Giotto Top

    (192d), the sensors and the AS-i card. Be very careful not to do this with the electrical power supply still connected. (GB-IST-GIOT-0112) 10/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 11 (192) and the caps (192c) with the relevant gaskets, remove the terminal board (21c) or the solenoid valve board (192d) and the AS-I card (283). (GB-IST-GIOT-0112) 11/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 12: Assembling Giotto Top

    1. Fit the air fittings (21e and 21g), the air caps (21i) and the air vent (21f). Screw the electrical connection in place (114a) or the cable gland sleeve (114c). (GB-IST-GIOT-0112) 12/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 13 (21c) or the AS-i card (283). 3. Screw the double guide (21d), the inductive sensor block (27d) and any inductive sensors (27a) (GB-IST-GIOT-0112) 13/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 14 Always MAKE SURE the electrical and pneumatic connections are NOT activated whilst working on Giotto Top and that the power supply voltage ® is always and only 24 Vdc. (GB-IST-GIOT-0112) 14/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 15: Electrical Connections

    9. Electrical connections (GB-IST-GIOT-0112) 15/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 16 8. Electrical Connections (GB-IST-GIOT-0112) 16/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 17 8. Electrical Connections (GB-IST-GIOT-0112) 17/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 18: Installing Solenoid Valves

    (192b) and the seal rings of the support (192e). Fit the air fitting (21i) and connect the additional solenoid valve to the LEDs terminal board. (GB-IST-GIOT-0112) 18/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 19 Make sure the distance from the stem is less than 1.5 mm to ensure correct operation. (GB-IST-GIOT-0112) 19/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 20: Trouble Shooting

    NOT live or pressurised while working on Giotto Top and that the power ® supply voltage is always and only 24 Vdc. (GB-IST-GIOT-0112) 20/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 21: Maintenance

    (GB-IST-GIOT-0112) 21/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 22 13. Part list (GB-IST-GIOT-0112) 22/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 23 13. Part list (GB-IST-GIOT-0112) 23/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 24: Parts List

    Terminal board + support Cover Cable with plug 114a Male connector 114b Female connector 114c Sleeve for cable gland Solenoid valve AS-i cards (GB-IST-GIOT-0112) 24/25 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 25: Warranty

    S.p.A. shall be liable should any such defects be found within 12 (twelve) months from the date of delivery of the products. 1.2 Any claim regarding defects and/or faults found in the products shall be notified in full and in writing to Bardiani Valvole S.p.A.