The dipswitches are set in binary code (1=switch 1 on). To work out how you need to set the
dipswitches to get a certain channel number, use the following step-by-step procedure:
Step 1: Is number more than 256? If so turn switch 9 on and subtract 256.
Step 2: Is number more than 128? If so turn switch 8 on and subtract 128.
Step 3: Is number more than 64? If so turn switch 7 on and subtract 64.
Step 4: Is number more than 32? If so turn switch 6 on and subtract 32.
Step 5: Is number more than 16? If so turn switch 5 on and subtract 16.
Step 6: Is number more than 8? If so turn switch 4 on and subtract 8.
Step 7: Is number more than 4? If so turn switch 3 on and subtract 4.
Step 8: Is number more than 2? If so turn switch 2 on and subtract 2.
Step 9: Is result 1? If so turn switch 1 on.

If you are using the Abstract CE controller, it can show you a picture of how to set the dip switches

for the channel you want. If you have a calculator which can display binary, just convert the
channel number to binary and turn on the '1' bits (switch 1 is the right hand bit).