Cornell Communications, Inc 4800 Design Guide 10-20-16 Table of Contents Cover … Table of Contents ... Cautions and Warnings ... System Components … 4800 System Riser … System Layout Options … Dedicated Phone Line Connection … VoIP Phone Line Connection …...
4. Caution - The 4800 Digital Emergency Communication System requires an Analog “POTS” dedicated telephone line for “Offsite” modem communication. 1. Warning – Cornell Communications manufactures proprietary Control Panels and Switches that have 8 available RJ45 ports to connect to additional Remote Control Panels, Switches and Call Stations. These devices connect using the straight-thru, TIA/EIA 568A or TIA/EIA 568B, wiring standard.
Consult the 4800 System Installation Manual for detailed system explanation prior to completing this guide. Please contact your Cornell Regional Account Manager for assistance with any questions or concerns regarding system layout and design.
Cornell Communications, Inc 4800 Design Guide 10-20-16 System Layout There are many different types of facilities and building layouts. Single story buildings will have a general floor plan that can provide the lineal footage, to ensure the 4800 system is installed within the distance limitations provided.
Page 8
The Expansion Switch (ES) can support up to (8) Call Stations (CS), or a combination of Control Panels, Expansion Switches and Call Stations. These are just a few small scale examples of the 4800 system capabilities. For large capacity applications, questions or concerns, please contact your Cornell Regional Account Manager for assistance.
Cornell Communications, Inc 4800 Design Guide 10-20-16 Dedicated Phone Line Connection The 4800 Digital Emergency Communication System has an internal modem that can be connected to an Analog “POTS” dedicated telephone line, as shown in the diagram below. Shared Phone Line Connection The 4800 Digital Emergency Communication System also incorporates a telephone line “Seizure”...
The Cisco adapter emulates the “POTS” line by providing DTMF tones and line voltage. Requirements: • Active Internet & Voice over IP accounts o VoIP adapter model confirmation is required for each individual VoIP service. (Cornell completed the operational testing using VoIP service provided by Nextiva) Disclaimers: The 4800 offsite notification process requires a standard “POTS”...
Cornell Communications, Inc 4800 Design Guide 10-20-16 POTS Phone Line Options. Cont Cellular Service A Shield Tech Security STS-GSMC-4G GSM Dialer has been tested and found to be a viable alternative to the “POTS” line connection. The Shield Tech Dialer emulates the “POTS” line by providing DTMF tones and line voltage.
Cornell Communications, Inc 4800 Design Guide 10-20-16 System Configuration The 4800 Emergency Communication System requires a minimum of: (1) A-4800M Main Control Panel, (1) BB-48 Flush Mount Enclosure, (1) 4800V Call Station, (1) B-5243B or B-5248A Power Supply, and the appropriate Signage.
Cornell Communications, Inc 4800 Design Guide 10-20-16 Maintenance Periodic Maintenance In general, the 4800 system will provide system fault information at the Control Panel(s) display. The “ACTION REQUIRED” LED represents an active call or a fault in the system that needs to be corrected.
(36) months from the date of manufacture, under normal use and service.* Obligation of CORNELL is limited to from the date of manufacture, under normal use and service.* Obligation of CORNELL is limited to from the date of manufacture, under normal use and service.* Obligation of CORNELL is limited to...