Installation
Pos: 11.24 /Montage/Aktorik/Elektr. Schwenkantriebe/RHDE250...4000/Gestaltung der Antriebselementnabe @ 12\mod_1189149161671_3101.doc @ 121126
Fig. 5: Stub shaft
Configuring the drive element hub
The new drive element is mechanically connected to the drive shaft via a hole with feather key
groove . This connection must be constructed so that the rated torque and any possible output
torque is transmitted accurately. The drive element must be mounted securely on the drive shaft
with suitable measures to prevent axial shift. For the new drive element, you can use the current
mechanical stops.
The following parameters must be observed:
Type
RHDE250
RHDE500
RHDE800
RHDE1250
RHDE2500
RHDE4000
Pos: 11.25 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830
18
bore diameter
mm (inch)
30 +0,033
(1.18 +0.0013)
50 +0,039
(1.97 +0.0015)
50 +0,039
(1.97 +0.0015)
70 +0,075/+0,030
(2.76 +0,0030/+0,0012)
70 +0,075/+0,030
(2.76 +0,0030/+0,0012)
85 +0,090/+0,036
(3.35 +0.0035/+0.0014)
RHDE250 ... 4000 (Contrac)
F
R
X
Key width mm
Hub length
(inch)
mm (inch)
8 -0,015/-0,051
(0.31 -0.0006/-
50 (1.97)
0.0020)
14-0,018/-
0,061
70 (2.76)
(0.55 -0,0007/-
0.0024)
14-0,018/-
0,061
70 (2.76)
(0.55 -0,0007/-
0.0024)
20-0,022/-
0,074
100 (3.94)
(0.79 -0.0311/-
0.0029)
20-0,022/-
0,074
100 (3.94)
(0.79 -0.0311/-
0.0029)
25-0,018/-
0,061
140 (5.51)
(0.98 -0,0007/-
0.0024)
M00347
Minimum yield
strength of hub Rp 0.2
2
N/mm
(pounds/square
inch)
320 (46412.80)
320 (46412.80)
320 (46412.80)
320 (46412.80)
320 (46412.80)
320 (46412.80)
42/68-167-EN