  • Page 1 Fixturlaser NXA pro Quick tips...
  • Page 2: Rough Alignment

    Fixturlaser NXA Pro P R E - A L I G N M E N T 1. Rough Alignment • Vertical: Place scale or straightedge on highest hub and raise or lower the movable shaft to within 0,5 mm of the stationary hub.
  • Page 3 Fixturlaser NXA Pro P R E - A L I G N M E N T Bolt Tightening Sequence 4. Make a Final Soft Foot Correction Loosen one bolt at a time and check for soft foot with a 0,05 mm shim or feeler gauge. Correct any foot with 0,05 mm or more of soft foot, then tighten the bolt before proceeding to the next foot.
  • Page 4 Fixturlaser NXA Pro S E T Set Up Turn on the Fixturlaser NXA Display Unit. Mount the ‘S’ sensor on the stationary shaft or cou- pling hub and hand tighten the nut. Turn the sensor on by pressing the power button.
  • Page 5: Enter Dimensions

    Fixturlaser NXA Pro M E A S U R E Enter Dimensions Touch the tape measure icon on the moveable machine image Measure the indicated dimension to the nearest 1 mm for coupling dimensions or 2 mm for foot dimensions enter using the keypad.
  • Page 6 Fixturlaser NXA Pro M E A S U R E Rotate the sensors to the 9:00 position and press the flashing measurement button. Rotate the sensors to the 12:00 position, being sure they move outside the red portion of the circle on the screen.
  • Page 7: Evaluating The Results

    Fixturlaser NXA Pro M E A S U R E Press the measurement button again to take the final reading. The results will be displayed on screen. Evaluating the Results Vertical results are displayed at the top of the screen, horizontal results at the bottom.
  • Page 8 Fixturlaser NXA Pro C O R R E C T I O N Using the Verti-Zontal Process ™ First Correct the Vertical Misalignment Press the shim icon in the bottom right corner of the screen. Then press it again on the confirmation pop-up screen.
  • Page 9 Fixturlaser NXA Pro C O R R E C T I O N If the sensors are not in proper position, a pop-up will appear showing their position and with narrow green slivers indicating where the sensors must be in order to take live readings.
  • Page 10 Fixturlaser NXA Pro R E - M E A S U R E & D O C U M E N T Re-Measure Press the re-measure button, then press it again on the confirmation pop-up screen. Re-measure to verify the results are within tolerance.
  • Page 11 Welcome to our world Since the very beginning in 1984, ACOEM AB, (formerly known as ELOS Fixturlaser AB) has helped industries throughout the world to achieve more profitable and sustainable production. We have reached where we are today by having the courage to think beyond the norm and follow slightly unconventional paths.