Gas Supply Connection - NAYATI NGETL 5-50 CE Installation, Operation And Maintenance Instructions

Gas economic table low
Table of Contents

Advertisement

• Gas Supply Connection

-
Before installing and connecting Gas Economic Table Low to gas supply, carefully
control the fixed part of gas system, which conformed to National Building
Regulation.
-
Verify gas pipes sections to guarantee sufficient supply for all gas heated
appliances. Install it in similar condition to avoid excessive pressure drops.
-
The pipes must be made of steel (with junctions made using white cast iron, or
galvanized steel fittings, or autogenously welded joints) or copper pipes (with
mechanical joints and couplings without seals or mastics or brazed joints).
-
Control the gas bottle (if any) placed correctly and protected in dry area.
-
Check whether the gas pipes can easily inspected. If the pipes installed in floor
and wall, make sure that this work done according to professional standard with
reference points that make it possible to find the pipes.
-
Before installing Gas Economic Table Low, makes sure that it is set for the gas
and pressure (see Technical Data Plates). Consult the paragraph "Gas
Conversion".
-
Connect Gas Economic Table Low to gas supply using solid fittings or flexible
steel pipes with suitable sections related to nominal power and length.
-
Check whether the flexible pipes does not pass or near hot surfaces, put under
stress and traction, contact with sharp edges, or other things that could damage
the pipe.
-
Install quick ON – OFF valve between the gas mains and each single appliance
where easy to reach.
-
After install Gas Economic Table Low safely, take a pressure test the whole gas
circuit by using leak finder spray or non-corrosive foams.
ORIENTAL
Manual Instructions for Gas Economic Table Low
15

Hide quick links:

Advertisement

Table of Contents
loading