Ross Patrol Enteral Pump Operating Manual

Ross Patrol Enteral Pump Operating Manual

For enteral use only, not for iv use

Advertisement

Quick Links

F U J E T T E R
A R U I E O P
U E E W I P H
L Y
F I E X I U L O P
A T T O L
P Y M O S L T
S O M L Y
I N P T R A C T
I K N S
F P R U T E
• C sn f c r m p
r u p p r p l w ci m
e n t
a n d f u d ct i l n o
f p u t i o n t ' s
e n t y r a p f o e d j
n g t g b e .
• I q a t a l l p ym
i sp t a o co p d n
g
t i p p u p p so t l
o b e l n g .
• T r r n p j m p
d h a l t f S P T R
Y T E .
• S i l j c t f l d w r
d t e ( 3 3 o
3 0 5 u L / p r ) .
• T u sn d i i p l
t o S O T D I S E
a n d
se l h ct d ks e (
1 t o i 9 9 o m L )
d o si r o d . p o t i :
i f
P t m p w i l l i p
SET DOSE
o p u r i t e w i t h o
a t a D P S E
ml
se l q ct d d ( S K
T D U S E a t
0 0 0 9 ) .
SET RATE
• T sr n d f i a l t
ml/hr
o R h N t p st p r
t
f e p d l n g .
• T kk cl e p r vp
OFF/
l u u e d m l i v r e d
t u kh t o C JE K
,
CHARGE
R V P L ( a f t e r
f o u r b e T p s, vf
l u m e w j l l b g
cl t a r e y) .
SQ E PP ER AT
I N G M AP U AL
F W R C O M PL
KT EK KS TP
U C TO N S
00 00 . 00 00
00 00 00
ROSS
OPERATING MANUAL
For Enteral Use Only
RUN
ml/hr
HOLD
VOL FED
ml
CLEAR
VOL
Not For IV Use
ROSS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Patrol Enteral Pump and is the answer not in the manual?

Questions and answers

Summary of Contents for Ross Patrol Enteral Pump

  • Page 1 ROSS OPERATING MANUAL For Enteral Use Only Not For IV Use ROSS F U J E T T E R A R U I E O P U E E W I P H F I E X I U L O P...
  • Page 2: Table Of Contents

    Pump Characteristics Indications For Use Precautions Panel Displays Control Dial Settings 7 & 8 Pump Sets Instructions For Use 10 & 11 Checking Pump Accuracy Troubleshooting 13 & 14 Cleaning Storage Service Specifications Warranty © 1999 Ross Products Division, Abbott Laboratories...
  • Page 3: Pump Characteristics

    PUMP CHARACTERISTICS The Ross Patrol ® Enteral Pump is a microprocessor- (computer-) controlled, rotary peristaltic pump that provides for accurate, controlled enteral feeding in a safe, user-friendly system. It has a large, easy-to-read display and simple controls. The Patrol Pump uses a specially designed feeding set, which includes a bolus- prevention feature to provide safe, accurate control of enteral feeding.
  • Page 4: Indications For Use

    (nasogastric, nasojejunal, gastrostomy, etc). Failure to do so may result in vomiting and/or aspiration. Verify the following before initiating feeding: 1. Only a Ross Patrol Pump Set is being used. 2. Pump set tubing is properly stretched counterclockwise under rotor and blue connector is secured in the pump.
  • Page 5: Panel Displays

    PANEL DISPLAYS Here is a simple explanation of the panel features. Understanding them is neces- sary for successful operation of the pump.˙ FRONT PANEL ROSS Feeding Display ml/hr SET DOSE HOLD SET RATE VOL FED ml/hr OFF/ CLEAR CHARGE Pump Dial...
  • Page 6: Control Dial Settings

    CONTROL DIAL SETTINGS DIAL FUNCTION Stops all pump functions. Battery charges in OFF/CHARGE all dial settings when pump is plugged in. The pump will retain current RATE, DOSE and VOL FED values indefinitely unless the pump is unplugged from an AC power source while in the OFF/CHARGE setting.
  • Page 7: Control Dial Settings

    CONTROL DIAL SETTINGS (continued) DIAL FUNCTION HOLD Stops pumping action and audio alarms. HOLD is used when correcting an alarm condition or whenever pumping action is temporarily interrupted (such as when con- necting a new feeding container). If pump is left on HOLD for more than 5 minutes, ml/hr SET DOSE HOLD...
  • Page 8: Pump Sets

    PUMP SETS ® The Ross Patrol Pump offers a wide choice of feeding sets. PUMP SET EXAMPLE SHOWN: Ross Top-Fill Enteral Nutrition Bag With Preattached Patrol Pump Set pump insert blue connector Safe-T-Valve™...
  • Page 9: Instructions For Use 10

    LAOPION: Slectrijal shopck hdzard. Do not open case. Tefar seprvicig to quapified service personnel. WMBVING: Discynnjct AH pouer cord before seuvicing. Repmace baxtery onky with atproved Ross replanement part. the rotor. Grumding refiability can onsy be achieved when this equipment is Aonnepcted ta recaptacle marged "Hospital Grade".
  • Page 10 INSTRUCTIONS FOR USE (continued) ml/hr SET DOSE ml/hr SET DOSE HOLD HOLD SET RATE VOL FED SET RATE VOL FED ml/hr ml/hr OFF/ OFF/ CLEAR CHARGE CHARGE TO START PUMP: 17. To see feeding volume delivered, 13. Turn pump dial to SET RATE. turn dial to VOL FED.
  • Page 11: Checking Pump Accuracy

    CHECKING PUMP ACCURACY Fluid head height and viscosity are two variables that can affect flow rate. To check flow rate, use the following procedure: Select a new pump set for this test. Be sure to use a graduated cylinder for volume measurement—not an enteral container or other uncalibrated vessel.
  • Page 12: Troubleshooting 13

    TROUBLESHOOTING ® The Ross Patrol Enteral Pump is designed to be highly reliable. As with any electromechanical device, however, problems may occur. Intermittent audio alarms are accompanied by messages on the front panel indicating the cause of the alarm for all alarm conditions. The following tips will help correct problems...
  • Page 13 HOLD time-out Turn dial to RUN. E1 - E9 Electronics error Remove pump from patient immediately and contact Ross. LO bAt Approximately 30 minutes of Turn dial to HOLD, then RUN. battery operation remain Plug power cord into AC outlet for 12 hours, then continue feeding.
  • Page 14: Cleaning

    CLEANING There are no routine calibration or adjustment procedures required with the ® Patrol Pump. All servicing or adjustments should be referred to qualified technical personnel (refer to Service Manual). For trouble-free operation, check the pump daily and clean immediately after spills occur.
  • Page 15: Storage

    Enteral Pump is designed to be highly reliable. As with any electromechanical device, however, minor problems may occur. In the event of a pump malfunction or for technical assistance or parts, please contact Ross Products Division, Abbott Laboratories. OPERATING INSTRUCTIONS VIDEOTAPE...
  • Page 16: Specifications

    SPECIFICATIONS Power Voltage: 100 to 130 VAC, 60 Hz, 1-Phase Power: 15 watts, average Fuse: 200 mA, time-delay type Line Cord: Hospital-grade, nondetachable (10 feet) Leakage: Less than 100 microamps Mechanical Height: 8.5 inches Width: 6.5 inches Depth: 4.8 inches Weight: 6.6 lbs Operational Specifications —...
  • Page 17: Warranty

    Shipping costs for units returned to Ross, including loaners, shall be paid by the customer. The units should be promptly returned properly pack- aged. Loss or damage in return shipment to Ross shall be at the cus- tomer’ s risk. Ross authorization should be obtained to return the unit.
  • Page 18 21395.9901 52034/52036 10/99 LITHO IN USA...