TATAREK RT-14 User Manual

Controller of heating system with solid fuel boiler

Advertisement

Quick Links

Zakład elektroniczny TATAREK Jerzy Tatarek
50-559 Wroclaw, 75 Swieradowska st.
ph. (071) 367-21-67, 373-14-88, fax 373-14-58; Tax index number 899-020-21-48;
Bank account: BZ WBK S.A. WROCLAW 6910901522-0000-0000-5201-9335
www.tatarek.com.pl.; E-mail: tatarek@tatarek.com.pl
24
Zakład elektroniczny TATAREK Jerzy Tatarek
USER MANUAL
program version 2.1 (06.02.2014
CONTROLLER OF HEATING SYSTEM
WITH SOLID FUEL BOILER
The controller controls the heating system based on the solid fuel boiler in which by controlling the
efficiency of the blower the burning process is under control. The receivers of the heat are as follows:
Container of the Warm Applicable Water (WAW) and Heating System (CH). The controller
cooperates with the 3-way mixing valve in the heater or floor system and safety system of the return
temperature of the boiler.
1.Basic parameters
Power
Power consumption without load
Max connection power
Operation conditions
Housing protection class
Fuse
P
ower-carrying capacity
of blower output
Number of outputs to control pumps
Number of outputs to control the valve motor
Number of temperature sensors of water
Temperature sensor of the flue gas
Temp. measurement precision
Temp. measurement resolution
Switch-on temperature of the STB safety thermostat
RT14/2014/v.2.1/ANG
from program v2.1
)
RT-14
230V/50Hz
4W
750W
o
0-50 C, humidity10-90%
no condensation
IP41
6,3A/250V
1,5A/230V/50Hz
3 * 200W/230V/50Hz
2 * 200W/230V/50Hz
3 * KTY81 (0...+100 C )
PT1000 (-30...+450 C)
o
+/- 1 C
o
0,1 C
o
94 C
1
o
o

Advertisement

Table of Contents
loading

Summary of Contents for TATAREK RT-14

  • Page 1 RT14/2014/v.2.1/ANG Zakład elektroniczny TATAREK Jerzy Tatarek USER MANUAL program version 2.1 (06.02.2014 from program v2.1 RT-14 CONTROLLER OF HEATING SYSTEM WITH SOLID FUEL BOILER The controller controls the heating system based on the solid fuel boiler in which by controlling the efficiency of the blower the burning process is under control.
  • Page 2: Boiler Operation

    Admission Realization The text <xx> indicates the parameter “xx” whose detailed description is in ch. 9 Signature Remarks date date 2 Boiler operation The controller regulates the central heating system with the fine coal boiler, in which by controlling the efficiency of the blower the boiler temperature is changed. The fine coal CH boiler operates in the following cykle: firing-up - operation - damping: Phase I/Firing - up - t he controller turns on the blower.
  • Page 3 CE CONFORMITY DECLARATION Ref. No. 58.RT.01.2007/1/B ZAKŁAD ELEKTRONICZNY TATAREK Jerzy Tatarek 75 Swieradowska St. , 50-559 Wroclaw declare under our sole responsibility that the product: Controller of the Heating System model: RT-14 is in conformity with the basic requirements included in Directive EMC 2004/108/WE of 15.12.2004 (the electromagnetic compatibility law of 13.04.07) and Directive LVD 2006/95/WE of 21.08.07 (Laws...
  • Page 4: Warranty

    The controller protects the system from freezing, automatically switches on the circulating pump if the measured temperature is below 4 C. Zakład elektroniczny TATAREK Jerzy Tatarek The controller realizes an after-season rundown of the pump. The pump turns on for a minute if it 50-559 Wroclaw, 75 Swieradowska st doesn’t run for a week.
  • Page 5 POWER SUPPLY 230V/50Hz: 6. The WAW pump The controller is to be connected to the mains protected by an appropriate fuse for the used The controller controls the pump loading the WAW container. The cycle of loading starts if the WAW pumps and blower (typically 6,3A/230V): temperature sensor indicates a temperature below 50 C (”...
  • Page 6: Handling The Controller

    FUSE 8. Cooperation with the room thermostat The controller has an input to connect the room thermostat of any kind, equipped with an nonvoltage relay output. To the controller you connect the terminals of the thermostat which short-circuit if the MAINS room temperature is higher than the preset one.
  • Page 7: Alarm Screens

    1. Damage of the temperature sensor of the boiler (T1) 2. Damage of the temperature sensor of the WAW (T2). The alarm doesn’t start if the sensor is not WE INFORM THAT THE RT-14 CONTROLLER MAY BE USED ONLY TO THE APPOPRIATE DEVICES.
  • Page 8: Installing The Controller

    The fine coal CH (central heating) boiler operates in the following cycle: firing-up, operation, PASSWORD „9999” HAS CONSIDERABLE MEANING. IT CAUSES THE REACTIVATION OF THE damping: PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING DISCLOSED. is launched by pressing the F2 button. Transition to the next phases Phase 1/Firing-up PASSWORD OF PRODUCER'S SERVICE IS UNIQUE AND IS NOT DEPENDENT ON THE USER'S follows automatically.
  • Page 9 9.3 Screen of the WAW pump LEVEL OF PARAMETERS 2 PARAMETERS CAN BE CHANGED AT UNLOCKED PASSWORD Icons of accumulator additional NAME RANGE DEFAULT SETTING FUNCTION temperature data pumps F1=setting the basic 30...80 Minimal boiler temperature at which the CH pump (P1) Icon of T.onPumpCH parameters...
  • Page 10 9.4 Operation screen in safety system of boiler return temperature LEVEL OF PARAMETERS 2 PARAMETERS CAN BE CHANGED AT UNLOCKED PASSWORD The screen appears at the setting <60>(”ModeMIXER”)=RETURN Direction Boiler NAME RANGE DEFAULT SETTING FUNCTION Icons of of valve temperature additional boiler move...
  • Page 11 10 Parameters 9.5 Screen of the mixer operation in the floor system LEVEL OF PARAMETERS 1 The screen appears at the setting <60>(”ModeMIXER”)=FLOOR NAME RANGE SETTING FUNCTION DEFAULT Temperature Icons of behind the mixer OFF / additional Signal ZAŁ+ OFF- turning off sound alarm ł...
  • Page 12 9.6 Screen of setting the parameters Icon of On the first screen of the parameters the text "Level of Parameters" is shown. The text has a value of additional Icon of F1=change of data "0" that means the parameters are not available. After changing the level to "1","2" or "3" the MIXER and direction of valve following screens show parameter values.

Table of Contents