Zakład elektroniczny TATAREK Jerzy Tatarek
50-559 Wroclaw, 75 Swieradowska st.
ph. (071) 367-21-67, 373-14-88, fax 373-14-58; Tax index number 899-020-21-48;
Bank account: BZ WBK S.A. WROCLAW 6910901522-0000-0000-5201-9335
www.tatarek.com.pl.; E-mail: tatarek@tatarek.com.pl
24
Zakład elektroniczny TATAREK Jerzy Tatarek
USER MANUAL
program version 2.1 (06.02.2014
CONTROLLER OF HEATING SYSTEM
WITH SOLID FUEL BOILER
The controller controls the heating system based on the solid fuel boiler in which by controlling the
efficiency of the blower the burning process is under control. The receivers of the heat are as follows:
Container of the Warm Applicable Water (WAW) and Heating System (CH). The controller
cooperates with the 3-way mixing valve in the heater or floor system and safety system of the return
temperature of the boiler.
1.Basic parameters
Power
Power consumption without load
Max connection power
Operation conditions
Housing protection class
Fuse
P
ower-carrying capacity
of blower output
Number of outputs to control pumps
Number of outputs to control the valve motor
Number of temperature sensors of water
Temperature sensor of the flue gas
Temp. measurement precision
Temp. measurement resolution
Switch-on temperature of the STB safety thermostat
RT14/2014/v.2.1/ANG
from program v2.1
)
RT-14
230V/50Hz
4W
750W
o
0-50 C, humidity10-90%
no condensation
IP41
6,3A/250V
1,5A/230V/50Hz
3 * 200W/230V/50Hz
2 * 200W/230V/50Hz
3 * KTY81 (0...+100 C )
PT1000 (-30...+450 C)
o
+/- 1 C
o
0,1 C
o
94 C
1
o
o