Information Lighting - Honeywell Titan SCBA Training Manual

County of los angeles fire department
Hide thumbs Also See for Titan SCBA:
Table of Contents

Advertisement

A LED informational lighting component has been added to the Titan SCBA to allow the user and surround-
ing crew members to assess each unit's status. All rear facing informational lights are found on the two
PASS devices affixed to the lower right and left sides of the air cylinder. Informational lighting on the front
of the SCBA is located on the second stage regulator and PASS device.
An amber LED located on the left rear PASS indicates battery status. Under normal conditions this light will
remain off. In storage or when the SCBA is activated manually or by pressure from the cylinder, the amber
LED flashes every ten seconds to indicate a low battery condition.. An audible beep will also sound every 10
seconds to indicate a low battery condition. The SCBA may continue to be used until the incident is conclud-
ed. The batteries shall be replaced immediately following the incident.
The red LED located on the right PASS will begin to blink when the user's remaining air supply reaches
33%. An audible low air alarm will activate at the approximately the same time. A corresponding red LED
on the front of the HUD will begin to blink. The will notify others of the low air condition.
There is an LED light located on the lower half of each PASS device. The lights are designed to act as a vis-
ual reference. Alternating green LED's will blink every second during normal operation. The LED lights
will alternate blinking green and red as the PASS device begins its staged operation. At full alert, alternating
red LED's will blink once every second.
Amber LED indicates
low battery condition.
Rear Speaker
Red / Green LED
PASS Alarm Lighting

11. INFORMATION LIGHTING

17
Red LED indicates
low air condition
Rear Speaker
Red / Green LED
PASS Alarm Lighting

Hide quick links: