5.2 Requirements for Hazardous Locations

5.2.1 General Guidelines

1.
WARNING! MAKE SURE ALL CIRCUITS ARE DE-ENER-
GIZED PRIOR TO INSTALLATION.
2.
The LMS100 has been evaluated as an Installation
(Overvoltage) Category 1 / Pollution Degree 2 apparatus
per IEC 1010.
4
3.
The maximum altitude of operation is 6560 feet (2000
meters).
4.
The LMS100 is designed with both internal and external
protective earth (ground) terminals.
L
5.
Housing and cover are made from 316L SS. Assess
material suitability for the target environment
before deploying.
PRO
6.
Additional flamepath information available upon request.
DE
7.
Product label may be susceptible to electrostatic charge
!
buildup in Group III environments. Care should be taken
to prevent the buildup of electrostatic charge. Clean
only with a damp cloth
4
8.
Do not torque any attached conduits, thread adapters,
reducers, elbows, or cable glands beyond the manu-
ADHESIVE LAYER
3KXL000461U0100
SUBSTRATE LAYER
facturer's recommended installation torque. Torque
requirements for the LMS100's optional thread adapters
ADHESIVE LAYER
L
3KXL000460U0100
are listed below.
OVERLAMINATE LAYER
FM/FM-C Name Plate
PRO
DE
LMS100.XX.XX.XX.XX
!
SN: 3K650000000000
MAGNETIC SWITCH
K-TEK PRODUCTS
MADE IN USA
250V MAX
!
SEE MANUAL
!
60VA MAX
ADHESIVE LAYER
3KXL000461U0100
OI/LMS100
(NON-IS/NI)
SUBSTRATE LAYER
ADHESIVE LAYER
3KXL000460U0100
OVERLAMINATE LAYER
ATEX/IECEx Name Plate
K-TEK PRODUCTS
MADE IN USA
!
SEE MANUAL
!
OI/LMS100
4
OI/LMS100-EN Rev. A |
6
4
3
3
CLII DIV2 GP EFG T6; CLIII T6
CLI Zn2 AEx nC IIC T6...T1
Ex nC IIC T6...T1 Gc
FM
1A MAX
TYPE 4X; NO ACIDIC ATMOSPHERES / AUCUN ATMOSPHERES ACIDES; IS / NI
C
US
PER CONTROL DWG 3KXL130100G0022; CONDUIT SEAL REQUIRED WITHIN
APPROVED
2 IN / SCELLEMENT EXIGE SUR CONDUIT A 50 MM; -40°C ≤ T
LMS100.XX.XX.XX.XX
SN: 3K650000000000
MAGNETIC SWITCH
250V MAX
1A MAX
60VA MAX
0575
(NON-IS/NI)
-40°C≤T
≤70°C
A
3
LMS100 Magnetic Level Gauge Switch
3
Option
U8
E8
E9
5.2.2 Nameplate Marking Procedure (Declaration of Protec-
tion Concept)
Before installing the switch, permanently indicate the protec-
tion concept associated with the hazardous area by marking the
corresponding box on the product label. Only one box shall be
marked. The chosen protection concept cannot be altered and
shall govern the use of the product until end of life. If more than
one protection concept is marked, the switch must be removed
from the hazardous area immediately.
LMS100.XX.XX.XX.XX
SN: 3K650000000000
MAGNETIC SWITCH
K-TEK PRODUCTS
.700
MADE IN USA
250V MAX
1A MAX
!
SEE MANUAL
!
60VA MAX
OI/LMS100
(NON-IS/NI)
NI: CLI DIV2 GP ABCD T6
CLII GP EFG T6; CLIII T6
LMS100.XX.XX.XX.XX
SN: 3K650000000000
CLI Zn1 AEx d IIC T6...T1
MAGNETIC SWITCH
K-TEK PRODUCTS
Ex d IIC T6...T1 Gb
250V MAX
MADE IN USA
1A MAX
SEE MANUAL
!
!
Zn21 AEx tb IIIC T85°C...T450°C
60VA MAX
OI/LMS100
(NON-IS/NI)
II 2 G, Ex d IIC T6...T1 Gb
II 2 D, Ex tb IIIC T85°C...T450°C Db
FM14ATEX0029X, IECEx FMG 14.0015X
II 1 G, Ex ia IIC T6...T1 Ga
II 1 D, Ex ia IIIC T85°C...T450°C Da
FM14ATEX0030X, IECEx FMG 14.0015X
II 3 G, Ex nC IIC T6...T1 Gc
FM14ATEX0031X, IECEx FMG 14.0015X
Description
M20 adapter 316 SS
1/2 inch by 1/2 inch
NPT elbow
1/2 inch NPT by M20
elbow
2
4.000
NI: CLI DIV2 GP ABCD T6
XP: CLI GP ABCD T6
CLII DIV2 GP EFG T6; CLIII T6
CLII GP EFG T6; CLIII T6
CLI Zn2 AEx nC IIC T6...T1
CLI Zn1 AEx d IIC T6...T1
Ex nC IIC T6...T1 Gc
Ex d IIC T6...T1 Gb
Zn21 AEx tb IIIC T85°C...T450°C
2
FM
TYPE 4X; NO ACIDIC ATMOSPHERES / AUCUN ATMOSPHERES ACIDES; IS / NI
C
US
PER CONTROL DWG 3KXL130100G0022;
APPROVED
2 IN / SCELLEMENT EXIGE SUR CONDUIT A 50 MM; -40°C
4.00 [101.6]
XP: CLI GP ABCD T6
CLII GP EFG T6; CLIII T6
II 2 G, Ex d IIC T6...T1 Gb
II 2 D, Ex tb IIIC T85°C...T450°C Db
CLI Zn0 AEx ia IIC T6...T1
FM14ATEX0029X, IECEx FMG 14.0015X
II 1 G, Ex ia IIC T6...T1 Ga
Ex ia IIC T6...T1 Ga
II 1 D, Ex ia IIIC T85°C...T450°C Da
FM14ATEX0030X, IECEx FMG 14.0015X
Zn20 AEx ia IIIC T85°C...T450°C
0575
II 3 G, Ex nC IIC T6...T1 Gc
-40°C ≤T
≤70°C
FM14ATEX0031X, IECEx FMG 14.0015X
A
NO MODIFICATION PERMITTED WITHOUT APPROVAL
Title:
K-TEK PRODUCTS
Doc. Type:
18321 SWAMP ROAD
ARTWORK DRAWING
PRAIRIEVILLE, LA. 70769 USA
Prepared by:
The information contained herein is
Norman W Guidry
proprietary to and considered a trade
secret of ABB Inc., and shall not be
reproduced, in whole or
Part No.:
in part, without the written authorization
of ABB Inc.
3KXL000391U0200
2
CRITICAL / SCHEDULE DOCUMENT
NO MODIFICATION PERMITTED WITHOUT APPROVAL
Title:
NAMEPLATE DRAWING
K-TEK PRODUCTS
Doc. Type:
18321 SWAMP ROAD
ARTWORK DRAWING
PRAIRIEVILLE, LA. 70769 USA
Prepared by:
The information contained herein is
Norman W Guidry
proprietary to and considered a trade
secret of ABB Inc., and shall not be
reproduced, in whole or
Part No.:
in part, without the written authorization
3KXL000391U0100 3KXL000391U0109
of ABB Inc.
2
Recommended
Torque
32.5 Nm
35 Nm
35 Nm
1
REV
DESCRIPTION
APPROVED
-
ECN0915
E.F.
IS: CLI GP ABCD T6
CLII GP EFG T6; CLIII T6
CLI Zn0 AEx ia IIC T6...T1
Ex ia IIC T6...T1 Ga
Zn20 AEx ia IIIC T85°C...T450°C
1
REV
DESCRIPTION
APPROVED
CONDUIT SEAL REQUIRED WITHIN
≤ T
≤70° C
A
-
ECN0915
E.F.
IS: CLI GP ABCD T6
.700 [17.8]
IP66/IP67
≤70° C
A
CRITICAL / SCHEDULE DOCUMENT
FROM AGENCY / NOTIFIED BODY
LMS100 FM/FM-C
NAMEPLATE
Approved by:
IP66/IP67
Eric Fauveau
Drawing No.:
3KXL000391U0209
1
FROM AGENCY / NOTIFIED BODY
LMS100 ATEX/IECEx
Approved by:
Eric Fauveau
Drawing No.:
1
DA
DA
-
Resp.
PA/MP/
Lang.:
EN
Date:
08/05/1
Rev.:
-
Sheet:
1 of
Resp.
PA/MP/L
Lang.:
EN
Date:
08/05/14
Rev.:
-
Sheet:
1 of 1