  • Page 1 BRESLE TEST KIT SP7310 Operating Instructions (V1.0 0119)
  • Page 3: Table Of Contents

    INDEX Instrument Data Product Description Name/Article Standards Scope of Supply Instrument Layout and Functions Preparations Determine Test Area Instrument Preparations Calibration 8/10 ISO 11127-6 Maintenance When Something Goes Wrong Disclaimer...
  • Page 4: Instrument Data

    1 INSTRUMENT DATA 1.1 Product Description The TQC Sheen Bresle Kit complies with the ISO 8502-6 and ISO 8502-9 standards that describe the Bresle Method to assess the level of soluble salts using a Bresle patch or Bresle sampler, distilled water and a conductivity gauge.
  • Page 5: Instrument Layout And Functions

    2 INSTRUMENT LAYOUT AND FUNCTIONS Battery Compartment Selected Measurement Method (Cond-TDS-Salt) Battery Indicator Indication of Unit ( μS/cm of mS/m) Measured Value Temperature On Button Calibration Button (in menu mode ‘Exit‘ button) Menu Button (in menu mode ‘Scroll‘ button) Enter Button (in menu mode ‘Accept‘ button) Temperature Electrode EC/Conductivity Electrode...
  • Page 6: Preparations

    3 PREPARATIONS 3.1 Determine Test Area Select the section on the steel surface to be used as the test area for assessment of the total surface density of salts. It should preferably be dry and with no loosely adherent rust, dirt or moisture (dampness), so that the patch frame can properly adhere to the surface.
  • Page 7: Calibration

    3.3 Calibration Calibration prior to each use is desirable for a reliable measurement. Fill up the syringe with deionised water. Remove the plastic cap from the measuring Place the gauge flat on a flat surface. cell. Inject the deionised water in the measuring Push the CAL button.
  • Page 8: Use

    4 USE Take care to trap as less air as possible in the Remove the protective backing of the Bresle Place the Bresle patch with the adhesive patch. patch with its inner protective paper and side to the test surface. dispose.
  • Page 9 Write down the value as blank value. Empty the syringe. Empty the meter. Fill up the syringe with deionised water. Empty the syringe until there is 2,5 ml left Insert the 2,5 ml of deionised water into to take care that there are no air bubbles in the Bresle patch by injecting it through the the syringe.
  • Page 10 Inject 1,5 ml of this water into the When finished, extract the entire volume Turn the Digital Conductivity Meter back on. measuring cell of the Conductivity Meter. of water into the syringe and remove the syringe from the Bresle Patch. A value is shown on the display.
  • Page 11: Iso 11127-6

    5 ISO 11127-6 7 WHEN SOMETHING GOES WRONG Determination of the water soluble salts in mineral abrasives, When the instruments doesn’t perform the way you expected, usually conform ISO 11127-6. you can solve it yourself easily. Therefore read this part thoroughly before claiming warranty.
  • Page 12 www.tqcsheen.com...