Summary of Contents for Warner Electric CBC-200 Series

  • Page 1 MEX (55) 53 63 23 31 MTY (81) 83 54 10 18 ® QRO (442) 1 95 72 60 ventas@industrialmagza.com DIST. AUTORIZADO CBC-200 Series & CBC-200C Series Single Channel Adjust Clutch/Brake Controls Installation & Operating Instructions P-269 819-0407 An Altra Industrial Motion Company...
  • Page 2: Table Of Contents

    A red indicator setting the maximum current level. On the marked “SHORT” is illuminated whenever a CBC-200 series Channel 2 is a fixed output level short circuit condition occurs in either of the and an adjustable output on Channel 1. Output outputs.
  • Page 3: Specifications

    6011-448-003 the outputs. CBC-200-3 6011-448-004 Internal Adjustments: Current Range Selection via Chassis Versions DIP switch, SW1 CBC-200-C 6011-448-005 Current Ranges: CBC-200-C1 6011-448-006 Switch Setting CBC-200-C2 6011-448-007 Max Output, ma 60 175 245 305 CBC-200-C3 6011-448-008 Warner Electric • 800-825-9050 P-269...
  • Page 4: Mounting

    3. Bring the external potentiometer wires through the conduit entrance hole and wire the potentiometers to the appropriate terminals blocks as shown in (Figure 5) CBC-200-2, (Figure 6) CBC-200-1, or (Figure 7) CBC-200-3. Figure 1 Warner Electric • 800-825-9050 P-269...
  • Page 5 This completes the mounting of the control. The with the holes on the PC board. unit is now ready for final wiring. Refer to the wiring section for final wiring. Figure 2 Warner Electric • 800-825-9050 P-269...
  • Page 6: Electrical Connections

    If they are not used, this completes the wiring of the control. ❑ 4. For power applied clutch/brake arrangement proceed to the wiring ❑ 7. Double check all connections before diagram and section below. applying power. Figure 3 Warner Electric • 800-825-9050 P-269...
  • Page 7 4. For electrically released brake-clutch wiring section. If external potentiometers are arrangement proceed to the wiring section not used, this completes the wiring of the below. control. ❑ 7. Double check all connections before applying power. Figure 4 Warner Electric • 800-825-9050 P-269...
  • Page 8 MTY (81) 83 54 10 18 ® QRO (442) 1 95 72 60 ventas@industrialmagza.com DIST. AUTORIZADO External Potentiometer wiring for CBC-200 Series Controls Enclosed Models CBC-200-1 CBC-200-2 CBC-200-3 Depending on which control is being used, options for external potentiometer are available Figure 5 via terminal blocks on the PC board of the unit.
  • Page 9 5. For the CBC-200-2 reattach the internal the steady state output, channel 2. potentiometer knob. ❑ 6. Double check all wiring for both the poten- tiometer and the main terminal block to insure proper connections. Warner Electric • 800-825-9050 P-269...
  • Page 10 6. Make sure all terminals are securely fastened and the wiring cable is secured so that it can’t pull out. Note: The level adjustment controls both the current adjustable output, channel 1 as well as the steady state output, channel 2. Warner Electric • 800-825-9050 P-269...
  • Page 11: Internal Adjustments

    The internal DIP Switch on the control circuit board adjusts the control for the proper current range to the clutch and/or brake coil being used. The chart below indicates the proper setting based on coil resistance and Warner Electric product. To adjust for products not listed, obtain coil resistance information and set switches per coil resistance.
  • Page 12: Troubleshooting Checklist

    • Check setting of torque adjust potentiometer and set to maximum if required. Check for correct wiring if external pots are used. Magnets are incorrectly sized • Verify sizing is correct by repeating selection process. Warner Electric • 800-825-9050 P-269...
  • Page 13 MEX (55) 53 63 23 31 MTY (81) 83 54 10 18 ® QRO (442) 1 95 72 60 ventas@industrialmagza.com DIST. AUTORIZADO Notes: Warner Electric • 800-825-9050 P-269...
  • Page 14: Warranty

    Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. Warner Electric LLC’s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential, indirect, or incidental damages of any kind incurred by reason of the manufacture, sale or use of any defective product.

This manual is also suitable for: