INSTRUCTION MANUAL FOR EMERGENCY LED DRIVER

DESCRIPTION

This emergency lighting module is designed to convert a wide range of LED types, and is an ideal choice for converting
most standard LED luminaries and arrays containing from 3 to 20 (60V) LEDs in series.
This unit is designed to utilize the existing LED driver and panel layout (no need to break into the LED circuit) to be
dimmed to 3W in case of emergency.
The driver automatically adjust the output LED current to provide the best optimum match between the battery and the
load, providing maximum illumination whilst ensuring full battery duration. The driver is compatible with a wide range of
lighting LEDs.

WIRING DIAGRAM

BALLAST LUMEN FACTOR%
Luminaire Power
60%

IMPORTANT

It is recommended that the module is installed by a competent person ensuring the installation complies with the
neces-sary standards. Hytronik accept no resonsibility for injury, damage or loss, which may arise as a result of
incorrect installation, operation or maintenance.
The conversion requires an unswitched supoly for charging the battery and a switched supply for a maintained conversion.
HYTRONIK INDUSTRIAL LIMITED
Room D, 10/f, Tower A, Billion Center, 1 wang Kwong Road,
Kowloon Bay, Kowloon, Hongkong
T: 00852-35197525
E: info@hytronik.com
MODEL NO. : HEM02
5W
7W
10W
12W
43%
30%
25%
F: 00852-30116936
15W
20W
25W
20%
15%
12%
CHINA FACTORY
Block A6, Nan'pu Science & Technology Park, Hao'si,
Shajing Street, Bao'an District, Shenzhen, P.R.C. 518104
T: 86 755 27322200
F: 86 755 27308687
E: info@hytronik.com
W: www.hytronik.com
30W
35W
40W
10%
9%
8%
45W
50W
7%
6%

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEM02 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hytronik HEM02

  • Page 1 It is recommended that the module is installed by a competent person ensuring the installation complies with the neces-sary standards. Hytronik accept no resonsibility for injury, damage or loss, which may arise as a result of incorrect installation, operation or maintenance.
  • Page 2 ISOLATE BOTH MAINS SUPPLIES AND DISCONNECT THE BATTERY BEFORE INSTALLATION OR MAINTENANCE. High voltage could be present at the output terminals if the battery is not isolated. Warning Avoid running the LED mains driver and Emergency pack without the load connected. Failure to do so may result in damage to the LED array.

Table of Contents