  • Page 1 HD Plus 1000VA / 2000VA WITH SOLAR CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL...
  • Page 2 SAFETY INSTRUCTIONS Before using the product, please read carefully the warning messages and instructions on labels and user manual of this product and other components connected to the product. The product is designed to be connected with lead-acid battery only. Do not connect the product with other types of batteries. In the event flooded batteries are used, regular maintenance on the battery shall be performed.
  • Page 3 SCOPE OF WARRANTY The product comes with a standard 1-year warranty. This warranty includes all defects of design, components and manufacturing. The Warranty is void and does not cover any defects or damages caused by in any of the following circumstances: ...
  • Page 4: Table Of Contents

    TABLE OF CONTENT PRODUCT OVERVIEW ................1 Product Outlook ................2 Typical Application ................4 INSTALLATION ..................5 Safety Clearance ................5 Mounting Inverter on the Wall ............5 Batteries ................... 6 PV (solar) string................8 Connect AC Input Cables and Loads ..........9 AC Input Voltage Range Selector .............
  • Page 5: Product Overview

    1. PRODUCT OVERVIEW This is a DC-to-AC inverter with integrated solar battery charger, which can be used as a long run-time UPS (Uninterruptible Power Supply), an energy- saving solution or an automotive inverter (hereinafter referred to as “inverter”). The inverter accepts input power source from AC mains (utility), battery, and PV (solar) string and switches between various operation modes automatically depending on the operational conditions.
  • Page 6: Product Outlook

    1.1 Product Outlook Front Panel  Power ON/OFF button  LCD  LED indicators Rear Panel  Battery Input  AC input voltage range selector (refer to section 2.6)  AC input fuse  PV/Utility priority choice switch  AC input receptacle (refer to section 3.2) ...
  • Page 7 LCD Display LCD displays the power flow and input/output readings in a visualized graphic design which allows the user to understand the operation status easily. The backlight of LCD remains on whenever the inverter is working (including Standby Charging Mode and Fault Mode). Description Icon This icon is showed when AC input presents.
  • Page 8: Typical Application

    LED Indicators The operation mode of the inverter can be easily told by LED indicators. Please see the table below for details. Behavior Description Line Mode, battery is being charged but nearly full Blinks once every 2 Line Mode, battery is being charged and Green second not full...
  • Page 9: Installation

    2. INSTALLATION 2.1 Safety Clearance The minimum clearance to the wall shall be larger than 30cm in order to ensure proper ventilation. In the event the ambient temperature is high, it’s recommended to increase the distance of safety clearance to improve the heat dissipation. 2.2 Mounting Inverter on the Wall The inverter is designed to either be placed on horizontal surface or be mounted on the wall with various ways (as shown below).
  • Page 10: Batteries

    2.3 Batteries Determine the size of battery The inverter is designed with pre-set charging current and voltage. Given a fixed charging current, under-sized batteries may shorten the battery life while over-sized batteries may result in unreasonable recharging time. It’s recommended the batteries capacity shall be no less than 100Ah. Connect the battery cables •...
  • Page 11 Connect with multiple batteries While connecting multiple batteries, use the same brand/type for all batteries. Do not mix the battery bank with different brand/type of batteries. The user may connect the batteries in series in order to double the voltage connected to inverter.
  • Page 12: Pv (Solar) String

    2.4 PV (solar) string Selection of PV panel PV string is a connection of PV panels whose output voltage and current vary under different illumination. And just like battery, the PV panel can be connected in either series or parallel as per needed. Please consult the supplier of PV panel so that the operational voltage and current fall within the allowed range of the inverter as set out in the specification.
  • Page 13: Connect Ac Input Cables And Loads

    2.5 Connect AC Input Cables and Loads Connect the AC input cables and loads to the receptacles as shown below. 2.6 AC Input Voltage Range Selector A. “NARROW” setting: Set the selector to “NARROW” when connected with loads which are more sensitive on voltage range.
  • Page 14: Operation

    3. OPERATION After connecting batteries, AC input cables, and loads, the inverter is now ready to work. 3.1 Standby Charging Mode The battery can be charged without switching on the inverter, and such operation is called Standby Charging Mode. When AC input cable and battery is connected, the inverter will enter into Standby Charging Mode and LCD will be turned on with the following display.
  • Page 15: Operation Modes (After Powered On)

    3.2 Operation Modes (after powered on) Press the Power ON/OFF button to power on the inverter and the inverter will automatically enter into either of the operation mode according to the condition of AC input and PV input as shown in the table below, LINE MODE 1 AC input power is present but there is no PV power (e.g.
  • Page 16 Priority Setting Switch In LINE MODE 2, if priority setting switch is set to give PV priority and PV power is also strong enough to support load, the AC input will not be consumed even though it is present. This is deemed an energy-saving operation.
  • Page 17: Fault Mode

    BACKUP MODE 3 AC input is absent and PV power is strong enough to not only support the load but also charge the battery. As long as the PV power persists, the load can be powered continuously without consuming power from battery. 3.3 Fault Mode Inverter enters into Fault Mode when there is a fault event.
  • Page 18: Specification

    4. SPECIFICATION MODEL HD Plus1000-12 HD Plus2000-24 CAPACITY VA/W 1000VA/720W 2000VA/1300W NOMINAL BATTERY VOLTAGE LINE MODE Nominal Voltage 230V 170-280V (Narrow Range) INPUT Voltage Range 90-280V (Wide Range) Normal voltage 50Hz or 60Hz Voltage 230V Frequency Following the Utility OUTPUT Output Waveform Following the Utility EFFICIENCY...
  • Page 19 GENERAL Dimension 275mm*226mm*85mm (D x W x H) PHYSICAL Net Weight (kg) 2.50 2.47 Operating 0- 50°C, 5%-90 % relative humidity (non-condensing) Environment Storage ENVIRONMENT -15°C to 55°C, 5% to 95% humidity (non-condensing) Environment Noise Level Less than 50dB...
  • Page 20: Trouble Shooting

    5. TROUBLE SHOOTING Problem Possible Cause Remedial Action Re-charge the battery and check if Battery voltage is low the battery cables are well- connected No LCD display Battery is defective Replace the batteries Power button is not pressed Press and hold the power button Mains are normal but works in AC input is absent...
  • Page 21: Appendix A How To Select And Configure Pv Panels

    APPENDIX A How to Select and Configure PV Panels The following parameters can be found in each PV panel’s specification: • P : Max output power (W) • V : max power voltage (V) • V : open-circuit voltage (V) •...
  • Page 22 • Total I of the string shall be less than the max. charging current of the solar battery charger (40A for both 1000VA and 2000VA model) • Total V of the string shall be less than the max. PV input voltage of the solar battery charger (55V for both 1000VA and 2000VA model).
  • Page 23 Example 2 - How to connect 2000VA model to PV panels with the following parameters? • P : 120W • V : 17.45V • V : 21.7V • I : 7.01A • I : 8.76A (1) The max. PV input power for 2000VA model is 900W, 900W / 120W = 7.5 ⇒...
  • Page 24: Disposal

    DISPOSAL In the event the product reaches the end of its service life, please contact the local dealer for disposal instructions. The product must not be disposed of with the household waste. Disposal of the product at the end of its service life shall be done in accordance with applicable disposal regulations for electronic waste.