  • Page 1 USER MANUAL...
  • Page 2: General Precautions

    General Precautions 1. Before using this Inverter, read all instructions and cautionary markings on : (1) Inverter (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only lead-acid rechargeable batteries. Other types of batteries may cause damage and injury. 3.
  • Page 3 Introduction This Inverter is a DC-to-AC inverter with auto line-to-battery transfer and integrated charging system, serving as an extended run UPS, a standalone power source or an automotive inverter. Inverter supplies power from AC power and DC source. When AC cable is connected to a wall socket, utility power goes to connected equipment(s) and/or charges the battery set via charging system.
  • Page 4: Operation

    Operation Front Panel Controls and LCD display Shown below are the controls and indicator lights on the front of Inverter. POWER ON/OFF LCD display Figure 1 Front Panel Power On/Off Power on/off button is shown as above. Once Inverter has been properly installed and batteries are connected, press this button and Inverter will turn on automatically, and works in mains mode or inverter mode according to input AC source’s status.
  • Page 5 3. When in AC mode, it will display as below. 4. When in Battery mode, it will display as below. And the mark will flicker every 1second. 5. When in off charging mode, it will display as below. Battery capacity displays same as below item 5.
  • Page 6 8. Battery capacity definition in inverter mode (24V battery indication is as twice as 12V battery,the tolerance is ±0.2V ): When battery low, the mark will flicker every 1second. 9. Troubleshooting. When in fault mode, it will display as below. Fault code table Battery mode Line mode...
  • Page 7: Back Panel Description

    Back Panel Description Shown below are the components on the back of Inverter. ○ Figure 2 Back Panel ①DC Input Connector (Battery Terminal) ②Input Fuse ③AC Input Receptacle ④Output Receptacle(s) ⑤Input Voltage Range Selector : (Input voltage range is defined in specification chapter, and output voltage is the same as input voltage in mains mode) A.
  • Page 8: Battery Connection

    time when the Inverter transfer from Normal mode to Battery mode during power failure. Hence, you can connect the home equipments, such as light bulb, fan, fluorescent tube, or TV when you select this mode. Caution!! If you select the ‘Wide’ mode and connect the computer to the output of Inverter, the computer may reboot if the input voltage is too low to be accepted.
  • Page 9 Step 3- Connect battery cables to your batteries l Single battery connection: When using a single battery, its voltage must be equal to the voltage of Inverter Nominal Input Voltage (see specs) 12VDC l For the user operation safety, we strongly recommend that you should isolate the battery terminals before you start to operate the unit.
  • Page 10 l Series battery connection: When using multiple batteries in series, all batteries must be equal in voltage and amp hour capacity, and the sum of their voltages must be equal to the voltage of Inverter Nominal Input Voltage (see specs) 24VDC l Parallel battery connection: When using multiple batteries in parallel, each battery’s voltage must be equal to the voltage of Inverter Nominal Input...
  • Page 11 Specification IG500-12-C IG1000-12-C IG2000-24-C IG 1000-24-C MODEL CAPACITY VA/W 500VA/300W 1000VA/600W 2000VA/1200W 1000VA/600W INPUT Nominal Voltage 110/120VAC or 220/230/240VAC 90-145VAC or 170-280VAC (Narrow Range) Voltage Range 50-145VAC or 90-280VAC (Wide Range) OUTPUT Voltage 120VAC or 230VAC Voltage Regulation (Batt. Mode)