BRAHMA EUROGAS Series Quick Start Manual

Automatic control systems for forced draught burners for gaseous fuels

Advertisement

Quick Links

EUROGAS SERIES
TYPES VM41 VM42
AUTOMATIC CONTROL SYSTEMS FOR FORCED
DRAUGHT BURNERS FOR GASEOUS FUELS
4007_r00
DESCRIPTION
The automatic control systems of this series are suitable to
control forced draught burners for gaseous fuels for non-
permanent operation.
All these controls perform non-volatile lock-outs, condition
from which a restart of the system is only possible by
means of the control manual reset.
This range of controls is suitable to equip burners for
domestic and industrial heating. The VM41 control is
suitable for single flame applications, while the VM42
control is suitable for dual flame applications.

GENERAL FEATURES

The main features of this range are the following:
− EC - Type certification (CE Reg. N° 63AQ0625) in
accordance with Gas Appliance Directive 90/396;
− in accordance with EN 298 (European standard for
automatic gas burner control systems), prEN 676
(European standard for automatic forced draught
burners) and DIN 4788 (German standard for automatic
forced draught burners);
− flame monitoring by the rectification property of the
flame (ionization);
− two independent safety contacts for the gas valve
control;
− electrical service life at max.declared loading >250.000
− inbuilt manual reset;
− easy to install and wire;
− interchangeable with the relevant mechanical controls
as regards operation and dimensions;
− max. burner output for VM41:
− max. burner output for VM42: no limits.

TECHNICAL DATA

Power supply:
upon request:
Operating temperature range:
Ambient humidity:
Protection degree:
socket type NE
socket type N
Classification code (according to EN 298):
VM41
VM42
Flame failure during TS causes spark restoration.
Times:
-Prepurge time (TW)
-Safety time (TS):
VM41:
VM42:
-Drop out time on running flame failure: < 1 s
The times given on the burner control label correspond to
the values guaranteed. The actual values differ slightly
from the values given, pre-purge and waiting times are in
fact longer and safety time shorter than their nominal
values.
120KW according to prEN 676;
350KW according to DIN 4788;
230V-50/60Hz
110/120V-50/60Hz
-20°C
+60°C
95% max. at 40°C
IP 40
IP 40
FMCLXN
FTLLXN
20/30/40/50/60 s
2/3/4/5 s
2/3 s
1/4

Advertisement

loading

Summary of Contents for BRAHMA EUROGAS Series

  • Page 1 EUROGAS SERIES TYPES VM41 VM42 AUTOMATIC CONTROL SYSTEMS FOR FORCED DESCRIPTION DRAUGHT BURNERS FOR GASEOUS FUELS The automatic control systems of this series are suitable to control forced draught burners for gaseous fuels for non- permanent operation. All these controls perform non-volatile lock-outs, condition from which a restart of the system is only possible by means of the control manual reset.
  • Page 2 VM41 VM42 ACCESSORIES Power consumption, at starting up: 12 VA 15VA The controls are supplied with inbuilt reset button; the Power consumption, running: 9 VA 12VA enclosures are arranged for the fitting of strain relieves Contact rating: I max and/or cable holders on the sides (see fig.2). -Thermostat: cosϕ...
  • Page 3 − the intervention of limiters or safety devices causes a Regarding the connection of the control units, provisions such as strain reliefs, sufficient earth terminals and neutral safety shut-down according to the application. terminals should be present in the appliance or in external connection boxes.
  • Page 4 BRAHMA S.p.A. Via del Pontiere, 31 37045 Legnago (VR) Tel. +39 0442 635211 - Telefax +39 0442 25683 03/03/26 Subject to amendments without notice http://www.brahma.it E-mail : brahma@brahma.it 4007_r00...

This manual is also suitable for:

Eurogas vm41Eurogas vm42