Toyota Supra 2015 Wiring Diagram Manual page 217

Table of Contents

Advertisement

RADIATOR FAN AND AUTOMATIC
SYSTEM OUTLINE
1. HEATER BLOWER OPERATION
MANUAL BLOWER OPERATION
WHEN THE BLOWER CONTROL SW IS SET TO ANY BLOWER SPEEDS, THE A/C AMPLIFIER OPERATES AND THE
CURRENT TO DRIVE THE BLOWER MOTOR FLOWS FROM TERMINAL BLW OF THE A/C AMPLIFIER TO TERMINAL SI
OF THE BLOWER MOTOR CONTROL RELAY. THE CURRENT ACTIVATES THE RELAY AND THE VOLTAGE APPLIED TO
TERMINAL +B OF THE BLOWER MOTOR CONTROL RELAY IS OUTPUT AT TERMINAL M+ AS THE VOLTAGE FOR THE
SELECTED BLOWER SPEED. THE CURRENT THEN FLOWS FROM TERMINAL M+ OF THE BLOWER MOTOR
CONTROL RELAY TO TERMINAL 2
TERMINAL GND
GROUND, AND THE BLOWER MOTOR OPERATES AT THE BLOWER SPEED SELECTED.
AUTO FUNCTION
WHEN THE AUTO SW IS TURNED ON, THE A/C AMPLIFIER CALCULATES THE REQUIRED VENT TEMPERATURE BASE
ON THE SET TEMPERATURE AND INPUT FROM EACH SENSOR. THEN TERMINAL BLW OF THE A/C AMPLIFIER
INPUTS CURRENT TO TERMINAL SI OF THE BLOWER MOTOR CONTROL RELAY IN CONFORMITY WITH THE
REQUIRED VENT OUTPUT. THIS CURRENT ACTIVATES THE BLOWER MOTOR CONTROL RELAY SO THAT CURRENT
FLOWS FROM TERMINAL M+ OF THE BLOWER MOTOR CONTROL RELAY
TERMINAL 1
TERMINAL M- OF THE BLOWER MOTOR CONTROL RELAY
ACTIVATING THE BLOWER MOTOR. THE BLOWER MOTOR THEN OPERATES AT DIFFERENT STEPS IN CONFORMITY
WITH VARIABLE CURRENT FLOW OUTPUT FROM TERMINAL BLW OF THE A/C AMPLIFIER TO TERMINAL SI OF HE
BLOWER MOTOR CONTROL RELAY.
2. OPERATION OF AIR INLET CONTROL SERVO MOTOR
(SWITCHING FROM FRESH TO RECIRC)
WITH THE IGNITION SW TURNED ON, THE CURRENT FLOWS FROM HTR FUSE TO TERMINAL 2 OF THE AIR INLET
CONTROL SERVO MOTOR
GROUND, THE MOTOR ROTATES AND THE DAMPER STOPS AT RECIRC POSITION.
(SWITCHING FROM RECIRC TO FRESH)
WITH THE IGNITION SW TURNED ON, THE CURRENT FLOWS FROM HTR FUSE TO TERMINAL 2 OF THE AIR INLET
CONTROL SERVO MOTOR
GROUND, THE MOTOR ROTATES AND THE DAMPER STOPS AT FRESH POSITION.
3. OPERATION OF AIR VENT MODE CONTROL SERVO MOTOR
WITH THE IGNITION SW TURNED ON, THE CURRENT FLOWS FROM HTR FUSE TO TERMINAL IG OF THE A/C
AMPLIFIER
(SWITCHING FROM DEF TO FACE)
THE CURRENT FROM TERMINAL AOF OF THE A/C AMPLIFIER
SERVO MOTOR
TERMINAL 2
MOTOR ROTATES AND THE DAMPER MOVES TO FACE SIDE. WHEN THE DAMPER OPERATES WITH THE A/C SW AT
FACE POSITION, THE DAMPER POSITION SIGNAL IS INPUT FROM TERMINAL 3 OF THE SERVO MOTOR TO THE
TERMINAL TP0 OF THE A/C AMPLIFIER. AS A RESULT, CURRENT TO THE SERVO MOTOR CIRCUIT IS CUT OFF BY
THE AMPLIFIER, SO THE DAMPER STOPS AT THAT POSITION.
(SWITCHING FROM FACE TO DEF)
THE CURRENT FLOWS FROM TERMINAL AOD OF THE A/C AMPLIFIER
CONTROL SERVO MOTOR
GROUND, THE MOTOR ROTATES AND THE DAMPER STOPS AT THAT POSITION.
4. OPERATION OF AIR MIX CONTROL SERVO MOTOR
WHEN THE TEMPERATURE SW IS TURNED TO THE "COOL" SIDE, THE CURRENT FLOWS FROM TERMINAL AMC OF
THE A/C AMPLIFIER
TERMINAL AMH OF THE A/C AMPLIFIER
DAMPER OPENING ANGLE AT THIS TIME IS INPUT FROM TERMINAL 3 OF SERVO MOTOR TO TERMINAL TP OF THE
A/C CONTROL ASSEMBLY, THIS IS USED TO DETERMINE THE DAMPER STOP POSITION AND MAINTAIN THE SET
TEMPERATURE.
WHEN THE TEMPERATURE CONTROL SW IS TURNED TO THE "WARM" SIDE, THE CURRENT FLOWS FROM
TERMINAL AMH OF THE A/C AMPLIFIER
TERMINAL 1
TERMINAL AMC OF THE A/C AMPLIFIER, ROTATING THE MOTOR IN REVERSE AND SWITCHING
THE DAMPER FROM COOL TO WARM SIDE.
228
TERMINAL 1
TERMINAL 5
TERMINAL AIR OF THE A/C AMPLIFIER
TERMINAL 3
TERMINAL AOD OF THE A/C AMPLIFIER
TERMINAL 1
TERMINAL AOF OF THA A/C AMPLIFIER
TERMINAL 1 OF THE AIR MIX CONTROL SERVO MOTOR
TERMINAL GND
TERMINAL 2 OF THE AIR MIX CONTROL SERVO MOTOR
TERMINAL M- OF THE BLOWER MOTOR CONTROL RELAY
TERMINAL AIF OF THE A/C AMPLIFIER
TERMINAL 1 OF THE AIR VENT MODE CONTROL
TERMINAL 2 OF THE AIR VENT MODE
GROUND AND THE MOTOR ROTATES. THE
TERMINAL 2 OF THE BLOWER MOTOR
TERMINAL GND
TERMINAL GND
TERMINAL GND
TERMINAL GND
GROUND. THE
TERMINAL GND
MOTOR
TERMINAL 2
GROUND,
MOTOR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents