We reserve the right for technical modifications without prior notice. HART® is a registered trademark of HART Communication Foundation. Technical Specifications: BPLV700 Pasve™ is a trademark of Satron Instruments Inc. Installation and Setting-Up Instructions: BPLV700AV Hastelloy® is the registered trademark of Haynes International.
BPLV700AV SATRON VG pressure transmitter 2006-12-19 1. INSTALLATION 1.1 Mechanical installation Mounting recommendations: Fig. 1-1 • Process connection direction: horizontal • Cable entry direction: from below • Connector coupling direction, calibration direction: horizontal Other considerations: • Steam should not be admitted to the transmitter’s sensing element.
Page 3
BPLV700AV SATRON VG pressure transmitter 2006-12-19 1.1.1 Installing welded process couplings Mounting hole for coupling • Make a 45.5 mm (+0.5/-0.2 mm) hole in the tank wall Ø or pipe, as shown in Figure 1-3. Welding the coupling These instructions apply to all welded couplings; welding the G1 standard coupling is described here as an example.
Page 5
BPLV700AV SATRON VG pressure transmitter 2006-12-19 Three process sealing options for the transmitter: AISI316L diaphragm, Viton O-ring (selection code 1) AISI316L diaphragm, PTFE O-ring (selection code 2) AISI316L, Hast. C276 G1/2 M546195, male G1/2A or tantalum diaphragm, M550393, female G1/2...
BPLV700AV SATRON VG pressure transmitter 2006-12-19 1.2 Electrical connections Supply voltage and load of the transmitter according to the figure 1-16. We recommend shielded twisted-pair cable as signal cable. The signal cable should not be installed near high-voltage 1. Remove screw cables, large motors or frequency converters.
Page 7
BPLV700AV SATRON VG pressure transmitter 2006-12-19 DN UP Test Load Power Figure 1-18, wiring housings H and T 1300354155 Test Load Power Figure 1-19, wiring housing M 1300354155 Test Load Power Figure 1-20, wiring housing N 1300354155...
BPLV700AV SATRON VG pressure transmitter 2006-12-19 2 SETTING UP 2.2 Setting up through HART® 275 user 2.1 Using the 275 user interface interface Operation keys The six operation keys are located above the alphanumeric After installing and connecting the transmitter, connect the keyboard: user interface to the transmitter.
Page 9
BPLV700AV SATRON VG pressure transmitter 2006-12-19 2.3 Using the 375 user interface The following menu is then displayed: 1 Measurement 2 Configuration 3 Information 4 Diagnostics 5 Review To change the measurement unit, damping time constant or output mod, select Configuration.
2.5 Setting-up with Satron-pAdvisor Service Software When you will have available all the operations of the Smart transmitter, we recommend the use of Satron-pAdvisor Service Software program in setting-up. Satron Instruments Inc. will deliver you the program, HART-modem and CAL- BOX according the order.
Page 11
BPLV700AV SATRON VG pressure transmitter 2006-12-19 275 software tree Measurement (Valmet transmitters) Pres. % rnge Sensor Housing 4 mA Configuration Range values Min Span Apply values 20 mA Damping Pres. unit Tempr. unit ON LINE Detailed config Alarm current Write protect Lin.func...
Page 12
BPLV700AV SATRON VG pressure transmitter 2006-12-19 275/375-software tree (Satron transmitters) Measurement Press % rnge Min Span 4 mA Sensor Apply values Housing 20 mA Damping Alarm current Configuration Range values Output Lin. func User point cnt User function data User unit USER...
3.1 Adjustability Zero suppression and elevation Maximum zero suppression is 86 % of max.span, and Maximum span is 25 times the minimum span for SATRON maximum zero elevation is 100 % of max. span. Zero VG transmitter adjustments is made from outside the housing, under the Span adjustments is made from outside the housing, under protective rubber shield (figure 3-2).
The calibration stand shown in Fig. 3-3 or a similar arrangement is used to calibrate the transmitter. Figure 3 - 3 SATRON VG transmitter's calibration stand 3.2 Damping DN UP If pulsation occurs in the measured pressure, it can be damped with the damping trimmer position D under the protective rubber shiled on the housing.
Page 15
- Module Information Temperature Interface Stage - Failure Piezoresistivity Module protection LCD-Display Sensor Keyboard Temperature - Test Connections Pressure - Cable Connections Analog Output Signal to Control HART® Digital Comm. System Figure 4-1 Functional construction of the SATRON VG pressure transmitter 1300354156...
BPLV700AV SATRON VG pressure transmitter 2006-12-19 4. CONSTRUCTION AND Electronics Module The electronics module converts the process pressure OPERATION signal from the sensor module to 4-20 mA output signal. 4.1 Smart transmitter The conversion can be made in linear, square root or...
Page 17
BPLV700AV SATRON VG pressure transmitter 2006-12-19 Figure 5-2 Parts list:Enclosure with remote electronics 1300354163...
Page 18
BPLV700AV SATRON VG pressure transmitter 2006-12-19 1300354161 Figure 5-3 Parts list: Enclosure M, housing with terminal board Figure 5-4 Parts list: Enclosure N, housing with display 1300354162...
Page 19
BPLV700AV SATRON VG pressure transmitter 2006-12-19 Number Name Order number Name Order number Number Sensing element * 13 Protection cup, housing H, Seal T1300207 T1300295 M and T Device plug DIN43650 72900114 * 13 Protection cup, housing N T1300296 Cylinder-head screw...
Page 20