Technical Specifications: BPLV700
Installation and Setting-Up Instructions: BPLV700AV
Contents:
We reserve the right for technical modifications without prior notice.
HART® is a registered trademark of HART Communication Foundation.
Pasve™ is a trademark of Satron Instruments Inc.
Hastelloy® is the registered trademark of Haynes International.
Viton® is the registered trademark of DuPont Down Elastomers.
Satron Instruments Inc.
P.O.Box 22, FIN-33901 Tampere, Finland
Tel.int. +358 207 464 800, Telefax +358 207 464 801
www.satron.com, info@satron.com
Spare Parts List
BPLV700AV
Man.rev.2
2006-12-19

Advertisement

Table of Contents
loading

Summary of Contents for satron VG

  • Page 1: Table Of Contents

    We reserve the right for technical modifications without prior notice. HART® is a registered trademark of HART Communication Foundation. Technical Specifications: BPLV700 Pasve™ is a trademark of Satron Instruments Inc. Installation and Setting-Up Instructions: BPLV700AV Hastelloy® is the registered trademark of Haynes International.
  • Page 2: Installation

    BPLV700AV SATRON VG pressure transmitter 2006-12-19 1. INSTALLATION 1.1 Mechanical installation Mounting recommendations: Fig. 1-1 • Process connection direction: horizontal • Cable entry direction: from below • Connector coupling direction, calibration direction: horizontal Other considerations: • Steam should not be admitted to the transmitter’s sensing element.
  • Page 3 BPLV700AV SATRON VG pressure transmitter 2006-12-19 1.1.1 Installing welded process couplings Mounting hole for coupling • Make a 45.5 mm (+0.5/-0.2 mm) hole in the tank wall Ø or pipe, as shown in Figure 1-3. Welding the coupling These instructions apply to all welded couplings; welding the G1 standard coupling is described here as an example.
  • Page 5 BPLV700AV SATRON VG pressure transmitter 2006-12-19 Three process sealing options for the transmitter: AISI316L diaphragm, Viton O-ring (selection code 1) AISI316L diaphragm, PTFE O-ring (selection code 2) AISI316L, Hast. C276 G1/2 M546195, male G1/2A or tantalum diaphragm, M550393, female G1/2...
  • Page 6: Electrical Connections

    BPLV700AV SATRON VG pressure transmitter 2006-12-19 1.2 Electrical connections Supply voltage and load of the transmitter according to the figure 1-16. We recommend shielded twisted-pair cable as signal cable. The signal cable should not be installed near high-voltage 1. Remove screw cables, large motors or frequency converters.
  • Page 7 BPLV700AV SATRON VG pressure transmitter 2006-12-19 DN UP Test Load Power Figure 1-18, wiring housings H and T 1300354155 Test Load Power Figure 1-19, wiring housing M 1300354155 Test Load Power Figure 1-20, wiring housing N 1300354155...
  • Page 8: Setting Up

    BPLV700AV SATRON VG pressure transmitter 2006-12-19 2 SETTING UP 2.2 Setting up through HART® 275 user 2.1 Using the 275 user interface interface Operation keys The six operation keys are located above the alphanumeric After installing and connecting the transmitter, connect the keyboard: user interface to the transmitter.
  • Page 9 BPLV700AV SATRON VG pressure transmitter 2006-12-19 2.3 Using the 375 user interface The following menu is then displayed: 1 Measurement 2 Configuration 3 Information 4 Diagnostics 5 Review To change the measurement unit, damping time constant or output mod, select Configuration.
  • Page 10: Setting Up With Satron-Padvisor Service Software

    2.5 Setting-up with Satron-pAdvisor Service Software When you will have available all the operations of the Smart transmitter, we recommend the use of Satron-pAdvisor Service Software program in setting-up. Satron Instruments Inc. will deliver you the program, HART-modem and CAL- BOX according the order.
  • Page 11 BPLV700AV SATRON VG pressure transmitter 2006-12-19 275 software tree Measurement (Valmet transmitters) Pres. % rnge Sensor Housing 4 mA Configuration Range values Min Span Apply values 20 mA Damping Pres. unit Tempr. unit ON LINE Detailed config Alarm current Write protect Lin.func...
  • Page 12 BPLV700AV SATRON VG pressure transmitter 2006-12-19 275/375-software tree (Satron transmitters) Measurement Press % rnge Min Span 4 mA Sensor Apply values Housing 20 mA Damping Alarm current Configuration Range values Output Lin. func User point cnt User function data User unit USER...
  • Page 13: Set-Up Calibration

    3.1 Adjustability Zero suppression and elevation Maximum zero suppression is 86 % of max.span, and Maximum span is 25 times the minimum span for SATRON maximum zero elevation is 100 % of max. span. Zero VG transmitter adjustments is made from outside the housing, under the Span adjustments is made from outside the housing, under protective rubber shield (figure 3-2).
  • Page 14: Damping

    The calibration stand shown in Fig. 3-3 or a similar arrangement is used to calibrate the transmitter. Figure 3 - 3 SATRON VG transmitter's calibration stand 3.2 Damping DN UP If pulsation occurs in the measured pressure, it can be damped with the damping trimmer position D under the protective rubber shiled on the housing.
  • Page 15 - Module Information Temperature Interface Stage - Failure Piezoresistivity Module protection LCD-Display Sensor Keyboard Temperature - Test Connections Pressure - Cable Connections Analog Output Signal to Control HART® Digital Comm. System Figure 4-1 Functional construction of the SATRON VG pressure transmitter 1300354156...
  • Page 16: Construction And Operation

    BPLV700AV SATRON VG pressure transmitter 2006-12-19 4. CONSTRUCTION AND Electronics Module The electronics module converts the process pressure OPERATION signal from the sensor module to 4-20 mA output signal. 4.1 Smart transmitter The conversion can be made in linear, square root or...
  • Page 17 BPLV700AV SATRON VG pressure transmitter 2006-12-19 Figure 5-2 Parts list:Enclosure with remote electronics 1300354163...
  • Page 18 BPLV700AV SATRON VG pressure transmitter 2006-12-19 1300354161 Figure 5-3 Parts list: Enclosure M, housing with terminal board Figure 5-4 Parts list: Enclosure N, housing with display 1300354162...
  • Page 19 BPLV700AV SATRON VG pressure transmitter 2006-12-19 Number Name Order number Name Order number Number Sensing element * 13 Protection cup, housing H, Seal T1300207 T1300295 M and T Device plug DIN43650 72900114 * 13 Protection cup, housing N T1300296 Cylinder-head screw...
  • Page 20 BPLV700AV SATRON VG pressure transmitter 2006-12-19 MEETS THE COUNCIL OF THE EUROPEAN UNION DIRECTIVE 89/336/EEC FOR ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS. Satron Instruments Inc. P.O.Box 22, FIN-33901 Tampere, Finland Tel.int. +358 207 464 800, Telefax +358 207 464 801...

Table of Contents