schmersal EX-T. 454 Series Operating Instructions Manual
schmersal EX-T. 454 Series Operating Instructions Manual

schmersal EX-T. 454 Series Operating Instructions Manual

Belt alignment switches, position switches

Advertisement

Quick Links

Operating instructions
Belt alignment switches, position switches
Operating instructions. . . . . . . . . . . . .pages 1 to 6
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .4
4.2 Switch travel diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the
safe operation and disassembly of the the product. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The product must be exclusively used in accordance with the versions
listed below or for the applications authorised by the manufacturer.
Detailed information regarding the range of applications can be found in
the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of
the component, personal hazards or damage to machinery or
plant components cannot be excluded.
EN
EX-T. 454
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX-T. 454 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal EX-T. 454 Series

  • Page 1: Operating Instructions

    Product description Further technical information can be found in the Schmersal 2.1 Ordering code .........2 catalogues or in the online catalogue on the Internet: 2.2 Special versions.
  • Page 2 Appropriate accessories can be found in the resulting from such invasive work, arbitrary repairs, conversions and/or Schmersal catalogues or in the online catalogue on the modifications to the device. Internet: www.schmersal.net.
  • Page 3 Operating instructions Belt alignment switches, position switches EX-T. 454 3. Mounting Roller lever A 3.1 General mounting instructions Fitting is only authorised in a de-energised condition Two mounting holes are available. The use of a protective ground wire is imperative. Please note the information concerning maximum belt speed, switching frequency and tightening torques provided in the technical data.
  • Page 4 Operating instructions Belt alignment switches, position switches EX-T. 454 Roller lever V 4. Electrical connection 4.1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de-energised condition. Only use EX cable glands which are authorised for the corresponding field of application.
  • Page 5 Operating instructions Belt alignment switches, position switches EX-T. 454 5. Set-up and maintenance 5.1 Functional testing The function of the component must be tested. The following conditions must be previously checked and met: 1. The installation is executed according to the instructions 2.
  • Page 6 Belt alignment switches, position switches EX-T. 454 7. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.

Table of Contents