schmersal EX-SHGV Operating Instructions Manual

schmersal EX-SHGV Operating Instructions Manual

Ex trapped key system

Advertisement

Quick Links

Operating instructions
EX Trapped key system
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .7
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications. There
are no residual risks, provided that the safety instructions as well as
the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded when safety switchgear is
used. The relevant requirements of the standard ISO 14119
must be observed.
EN
EX-SHGV/EX-SVE/EX-SVM
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX-SHGV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal EX-SHGV

  • Page 1: Operating Instructions

    2.4 Technical data .........4 Further technical information can be found in the Schmersal 2.5 Safety classification .
  • Page 2 2. Product description 2.3 Destination and use The trapped key system, consisting of the components EX-SHGV..., 2.1 Ordering code EX-SHGV/ESS..., EX-SVE..and EX-SVM..., has been designed, in This operating instructions manual applies to the following types:...
  • Page 3 "locked" position when the voltage supply is switched off. EX-SHGV/L01/…; EX-SHGV/R01/…; EX-SHGV/B01/… Insert the key from a EX-SHGV/ESS…, EX-SVE… or EX-SVM… in the key tumbler cylinder (1) and turn it into position (2). The interlocking device is unlocked, the safety guard can be opened. The key can only be returned into position (3) and withdrawn, when the safety guard is closed.
  • Page 4 Interlocking device with two key tumbler cylinders 2.4 Technical data EX-SHGV/LD1/…; EX-SHGV/RD1/… Solenoid Interlock EX-SHGV: Insert the key from a EX-SHGV/ESS…, EX-SVE… or EX-SVM… in the Equipment category: L II 2GD key tumbler cylinder (1) and turn it into position (3). The interlocking Ex protection: c 85°C X...
  • Page 5 In case of painting activities, the 2.5 Safety classification components must be covered. Interlocking device (type 2) EX-SHGV: Standards: ISO 13849-1 Key distribution station EX-SVM…...
  • Page 6 Operating instructions EX Trapped key system EX-SHGV/EX-SVE/EX-SVM 3.2 Dimensions Key distribution station All measurements in mm. EX-SVM1/…-6/…/E EX-SVM1/…-10/…/E Interlocking device EX-SHGV/R01/…; EX-SHGV/L01/…; EX-SHGV/B01/… 32,3 EX-SHGV/RD1/…; EX-SHGV/LD1/… 16 24 EX-SVM1/…-6/…/A EX-SVM1/…-10/…/A 32,3 Key-operated selector switch EX-SHGV/ESS21S2/…/103 ¤ 29,5 ¤ 6,6 ¤ 6,6 ¤...
  • Page 7 Operating instructions EX Trapped key system EX-SHGV/EX-SVE/EX-SVM 4. Electrical connection 5. Set-up and maintenance 4.1 General information for electrical connection 5.1 Functional testing The safety function of the safety components must be tested. The The electrical connection may only be carried out by following conditions must be previously checked and met: authorised personnel in a de-energised condition.
  • Page 8 Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

This manual is also suitable for:

Ex-svmEx-sve

Table of Contents