Ple-30-044 4-Way For Direct Controlled Hoist; Picture; Functional Description - Prolyft PLE-30-044 User Manual

Controllers for direct controlled hoist
Table of Contents

Advertisement

PLE-30-044
4-WAY FOR DIRECT CONTROLLED HOIST
3
4
8
FRONT SiDE
1.
19" 3U rack housing
2.
Front plate release bolts
3.
Mains switch 3 phase short circuit breaker
4.
Short circuit protection for power and control
5.
Up-0-Down switch for pre-selecting the individual hoist
direction
6.
Emergency button
7.
Run button
8.
Phase failure protection
BACKSiDE
9.
Power cable of 150cm with 32A-5p CEE plug with phase
reverse plug
10.
Output HARTING 16p connector
11.
Link option to daisy link multiple controllers for operating
lager quantity of hoist with Hirschmann CA3LS connector
©Prolyte Products Group 2009
Prolyte has made every effort to ensure the accuracy of this manual. No liability will be accepted for errors. Prolyte reserves the right to change or alter their products or
manuals without prior notice. No part of this manual may be reproduced in any form or by any means without prior written permission.
Prolyte Products Group – Phone +31 (0)594 85 15 15 Fax: + 31 (0)594 85 15 16 www.prolyte.com
5
6
1
7
9
10

FUNCTIONAL DESCRIPTION:

1.
Measure the main power supply to be sure the operating
voltage is correct and all the phases are present
2.
Release the emergency button by turning it anti-clockwise
3.
Connect the controller to the power supply and switch it
on using the main switch
4.
Connect power cords to each of the hoists to be operated.
4 single cords can be connected to one multi cord.
5.
Connect the power cords to the controller by using a
break-out (HARTING 16p > 4 x 16A 4p) or connect the
multi cord to the controller.
6.
Link the controllers if you want to operate more than
4-channels using one "run-button".
7.
Check if the pre-selection switches for all hoist are in the
"0 " position
2
8.
Select a hoist and switch it in the up or down direction.
Press the run button for 2 seconds to make sure the hoist
has power and if the running direction of the hoist
matches the selected direction on the controller.
Up is green LED, down is red LED.
9.
If the direction of the hoist is not correct, change phases
using the phase change plug on the power cable.
10.
If individual hoist run in the wrong direction, check
intermediate cabling or check the hoist.
11.
Make sure that the load to be lifted is in the correct
position
12.
Clear the area from obstacles
13.
No people are allowed under or on the load. Make sure all
11
people have left the operating area before you start to
move any load.
14.
Make sure you have an unobstructed view on the full
travel path of the load.
15.
Pre-Select all hoist needed in the up or down direction
16.
Press the run button to activate all hoists and hold it till the
load has reached the desired height. It may be necessary
to level the rig at certain stages.
17.
Never press the run button staccato. This can severely
damage controller and hoist.
18.
If the desired height is reached release the run button,
and switch of the mains power switch.
19.
In case more hoist need to be operated than the controller
allows, you can daisy link two or more controllers by
means of the link cable. The emergency breaker only
works for the controller from which the breaker is pushed!
Note! NEVER change the running direction of a hoist when the run
button is pushed
-
Use only cable and connectors, which are in
good condition
-
Never connect more than one hoist per
channel
-
Not respecting this manual can cause severe
injury or even death
USER MANUAL PLE-30