G G A A S S S S A A F F E E T T Y Y ( ( I I N N S S T T A A L L L L A A T T I I O O N N A A N N D D U U S S E E ) ) R R E E G G U U L L A A T T I I O O N N S S . .
It is the law that all gas appliances are installed by a competant person
in accordance with the above regulations.
BRITONY II.T NAT G.C. N° 52 980 04
BRITONY II.T LPG G.C. N° 52 980 09
from serial number 999508276-04
*
-
+
I I n n s s t t a a l l l l a a t t i i o o n n
a a n n d d S S e e r r v v i i c c i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s
(leave these instructions with the user)
The model number and serial number of this heater are on the data badge which is found inside the
rear case on the lower left hand side.
These numbers should be used when ordering replacement parts.
C C O O N N F F O O R R M M S S W W I I T T H H E E U U R R O O P P E E A A N N S S T T A A N N D D A A R R D D E E N N . . 2 2 6 6
c

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Britony II T and is the answer not in the manual?

Questions and answers

Summary of Contents for C&M Britony II T

  • Page 1 BRITONY II T Room Sealed Balanced Flue MULTI POINT WATER HEATER G G A A S S S S A A F F E E T T Y Y ( ( I I N N S S T T A A L L L L A A T T I I O O N N A A N N D D U U S S E E ) ) R R E E G G U U L L A A T T I I O O N N S S . .
  • Page 2 The BRITONY II T is a cat. II appliance 2H 3+ 809124535.02 BRITONY II T NAT GC N° 52 980 04 809124525.02 BRITONY II T LPG GC N° 52 980 09 The BRITONY II T is a balanced flue instantaneous gas fired multipoint water heater. For direct connection to the mains cold water supply.
  • Page 3: Technical Data

    Technical Data TABLE 1 Heat imput Nominal ..................23 kW - 78,480 Btu/h Heat output Nominal ..................21 kW - 71,650 Btu/h Gas rate (maximum) : • Natural gas (G 20) ................2.43 m /h - 88.1 ft • Butan (G 30)..................1.81 kg/h •...
  • Page 4 F F I I T T T T I I N N G G T T H H E E F F L L U U E E T T E E R R M M I I N N A A L L The BRITONY II T is supplied in two cartons, on containing the heater, the other containing the balanced flue set.
  • Page 5 I I n n s s t t a a l l l l a a t t i i o o n n I I N N S S T T A A L L L L A A T T I I N N G G T T H H E E H H E E A A T T E E R R The size of the gas supply pipe from the meter to the heater only should be as follows.
  • Page 6 Contact Chaffoteaux Limited for details of those machines know (III) A check should be made of all stop cocks in the incoming to be compatible with the BRITONY II T. supply and it should be ensured that they are of the fixed jumper pattern.
  • Page 7 S S e e r r v v i i c c i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Before commencing any servicing work, turn off the gas and Replace in reverse order making sure that the gasket between water at the gas and water inlet taps on the appliance.
  • Page 8 S S e e r r v v i i c c i i n n g g i i n n s s t t r r u u c c t t i i o o n n s s Re-assemble in reverse order ensuring that the skirt fixing screw 8 8 ) ) M M A A I I N N G G A A S S V V A A L L V V E E and reinforcing strip are in place.
  • Page 9 S S e e r r v v i i c c i i n n g g i i n n s s t t r r u u c c t t i i o o n n s s 1 1 6 6 ) ) G G A A S S C C O O N N V V E E R R S S I I O O N N 1 1 1 1 ) ) G G A A S S A A N N D D W W A A T T E E R R F F I I L L T T E E R R S S F F r r o o m m n n a a t t u u r r a a l l g g a a s s t t o o b b u u t t a a n n - - p p r r o o p p a a n n a a n n d d...
  • Page 10 FAULT FINDING CHART FOR BRITONY II T P P R R O O B B L L E E M M C C A A U U S S E E R R E E M M E E D D Y Y...
  • Page 11 FAULT FINDING CHART FOR BRITONY II T P P R R O O B B L L E E M M C C A A U U S S E E R R E E M M E E D D Y Y...
  • Page 12 SHORT LIST 1001 1018 1038 1019 1031 1043 1006 1006 1036 1036 Manf. date Key N° Description G.C N° Manf. Pt. N° Type from 366032 26773 FOAM SEAL 25x12 L: 1.030M 387251 35087 THERMOCOUPLE 387252 60703 ELECTRODE & LEAD ASSY 263432 25809.30 DIAPHRAGM...