Circuit Adjustments; Adjustments With Commander - Sony TRINITRON KV-J51PF2S Service Manual

Sony crt television user manual
Hide thumbs Also See for TRINITRON KV-J51PF2S:
Table of Contents

Advertisement

5-1. ADJUSTMENTS WITH COMMANDER

Service adjustments are made with the RM-869 that comes with
this unit.
Entering service mode
With the unit on standby
DISPLAY
5
VOL (+)
POWER
The operation sequence puts the unit into service mode.
1
4
7
÷
RM-869
SECTION 5

CIRCUIT ADJUSTMENTS

3
2
5
6
8
9
0
TV
[1], [4]
Raise/lower the service item number
[3], [6]
Raise/lower the data
[MUTING]
Writes
[0]
Executes the writing
[7], [0]
All data becomes the values in memory
[8], [0]
All user control goes to the standard state
[5], [0]
Service data initialization (Be sure not to use
usually.)
[2], [0]
Write 50Hz adjustment data to 60Hz, or
viceversa.
The screen display is :
Adjustment item
DATA
058S
RGB
08
0000
1000
Item number
[1], [4]
Select the adjustment item.
[3], [6]
Raise/lower the data.
[MUTING]
Writes
[0]
Executes the writing.
– 17 –
KV-J14P2S/J51PF2S
SERVICE
Mode
50
Depends on the signals
PAL, SECAM : 50
NTSC
: 60
RM-869