Declaration of Conformity as per Directive 2014/68/EU
The manufacturer
Pfeiffer Chemie-Armaturenbau GmbH, 47906 Kempen, Germany
PFA/PTFE-lined control valves
BR1a, BR1b, BR1c, BR1z, BR6a and BR8a
with PTFE bellows seal or diaphragm seal
declares that:
• with pneumatic/electric/hydraulic actuator
• with free shaft end for subsequent mounting of an actuator
1.
The valves are pressure accessories within the meaning of the Pressure Equipment Directive 2014/68/EU and
conform with the requirements of this Directive,
2.
They may only be operated observing the operating instructions <BA01a-01> delivered together with the valve.
The commissioning of these valves is only permitted after the valve has been installed from both sides in the pipeline and a
risk of injury can be ruled out.
(See section 2.3 for control valves intended for dead-end service)
Applied standards:
AD 2000 Regulations
Type designation and technical features:
Pfeiffer data sheets <TB01a, TB01b, TB01c, TB01z, TB06a and TB08a>
NOTE: This Manufacturer's Declaration applies to all valve types listed in this catalogue.
Applied conformity assessment procedure:
Conforming to Annex III of the Pressure Equipment Directive 2014/68/EU, Module H
Name of notified body:
TÜV Rheinland Service GmbH
Am Grauen Stein
51101 Köln
Germany
These Declarations become invalid when modifications are made to the control valves and/or assemblies that affect the
technical data of the control valve or the <Intended use> described in section 1 of the operating instructions, and considerably
change the valve or an assembly delivered with it.
Kempen, 1. August 2017
1 of 9
Specifications subject without notice
Edition: August 2017
T R A N S L A T I O N
Regulations for pressurized valve body parts
Marcus Miertz, Chief Executive Officer
Identification number of the notified body:
0035
Stefan Czayka, IMS Representative
Operating instructions BA 01a-01_EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Samson BR1a and is the answer not in the manual?

Questions and answers

Summary of Contents for Pfeiffer Samson BR1a

  • Page 1 AD 2000 Regulations Regulations for pressurized valve body parts Type designation and technical features: Pfeiffer data sheets <TB01a, TB01b, TB01c, TB01z, TB06a and TB08a> NOTE: This Manufacturer's Declaration applies to all valve types listed in this catalogue. Applied conformity assessment procedure:...
  • Page 2: Table Of Contents

    Operating instructions Control valve with PFA/PTFE lining actuated Contents Introduction Intended use Safety instructions General safety instructions Safety instructions for the operator Particular hazards Designation of the control valve Transport and storage Installation in the pipeline General Installation instructions Pressure check in pipeline section Standard operation and maintenance Troubleshooting Further information...
  • Page 3: Introduction

    Observation of conformity with the Directive 2014/34/EU Pfeiffer valves do not have their own potential ignition source according to the risk assessment in the rare incident of an operating fault in accordance with DIN EN 13463-1 and therefore do not fall within the scope of the Directive 2014/34/EU.
  • Page 4: Particular Hazards

    Preventing misuse of the control valve: It is especially important to make sure that the selected lining for wetted parts in the control valve is suitable for the media used as well as the prevailing pressures and temperatures. Failure to follow these safety precautions may result in personal injury and can damage equipment Warning installed in the pipeline.
  • Page 5: Designation Of The Control Valve

    Manufacturer Pfeiffer Address, see section 8 <Further information> Valve type BR (and number) e.g. BR 1a = Series 1a, see Pfeiffer catalogue Body material e.g.: EN-JS 1049 Material number acc. to DIN EN 1563 (formerly GGG 40.3) Size DN (and number) Value in mm, e.g.
  • Page 6: Installation In The Pipeline

     Store the valve in a closed room before it is installed. Protect it against damaging influences such as dirt or moisture.  Make sure, in particular, that the plastic-lined facings of the flanges intended to connect the valve in the pipeline are not damaged through mechanical or other influences.
  • Page 7  Make sure that only control valves are installed when their pressure rating, end connections and face to face dimensions match the conditions of application. See the designation of the control valve. Do not install a control valve if its permissible pressure/temperature ranges do not apply to the operating conditions.
  • Page 8: Pressure Check In Pipeline Section

    2 or 3 in section 4.2 <Installation instructions>. designation. Only use If the medium leaks out at the flanges of the lined valve: original parts from Pfeiffer. Leak at the Retighten the flange bolts using the torque specified in Table 2 or 3 in section 4.2 connection to the <Installation instructions>.
  • Page 9: Further Information

    When ordering spare parts, Remove the valve (observing the instructions in section 2.3 <Particular hazards>), include all the specifications dismantle the valve and replace the bellows seal. Contact Pfeiffer for spare parts and listed in the valve necessary instructions. designation. Only use For the permissible tightening torque to retighten the body halves of the valve, see original parts from Pfeiffer.