Operation Characteristic Curve; Capacity Variation Ratio According To Temperature; Cooling; Heating - Toshiba RAS-07TKVG-EE Service Manual

Split type
Hide thumbs Also See for RAS-07TKVG-EE:
Table of Contents

Advertisement

2-2. Operation Characteristic Curve

<Cooling>
10
9
RAS-16TKVG-EE
8
7
6
5
4
3
2
1
0
0
10 20 30 40 50 60 70 80 90 100 110
Compressor Speed (RPS)

2-3. Capacity Variation ratio According to Temperature.

<Cooling>
105
100
95
90
85
80
75
70
65
Capacity ratio : 100 %=
1.50kW(RAS-05TKVG-EE)
2.00kW(RAS-07TKVG-EE)
60
2.50kW(RAS-10TKVG-EE)
3.30kW(RAS-13TKVG-EE)
55
4.20kW(RAS-16TKVG-EE)
5.00kW(RAS-18TKVG-EE)
50
32
33
34
35
36
Outside Temperature (
RAS-05TKVG-EE
RAS-18TKVG-EE
RAS-13TKVG-EE
RAS-10TKVG-EE
RAS-07TKVG-EE
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 7.5m (18k Only)
Pipe Length : 5m
Voltage : 230V
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
C/WB 24
C
o
o
Indoor Air Flow : High
Pipe Length : 7.5m (18K only)
Pipe Length : 5m
Voltage : 230V
37
38
39
40
41
42
43
44
45
C)
o
<Heating>
10
9
8
7
6
5
4
3
2
1
0
0
10 20 30 40 50 60 70 80 90 100 110
<Heating>
120
100
80
60
40
2.00kW(RAS-05TKVG-EE)
Capacity ratio : 100 %=
3.20kW(RAS-10TKVG-EE)
2.50kW(RAS-07TKVG-EE)
20
5.00kW(RAS-16TKVG-EE)
3.60kW(RAS-13TKVG-EE)
5.40kW(RAS-18TKVG-EE)
0
-25
-20
46
- 9 -
FILE NO. SVM-19040
RAS-16TKVG-EE
RAS-18TKVG-EE
RAS-10TKVG-EE
RAS-05TKVG-EE
Conditions
Indoor : DB 20
Outdoor : DB 7
Indoor Air Flow : High
Pipe Length : 7.5m (18k Only)
Pipe Length : 5m
Voltage : 230V
Compressor Speed (RPS)
Conditions
Indoor : DB 20
C/WB 15
C
o
o
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 7.5m (18K only)
Pipe Length : 5m
Voltage : 230V
-15
-10
-5
0
5
Outside Temperature ( ºC)
RAS-13TKVG-EE
RAS-07TKVG-EE
C/WB 15
C
o
o
o
C/WB 6
o
C
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents