Generator/ Transmitter - C-SCOPE L2 Series Instruction Manual

Table of Contents

Advertisement

C.Scope Generator/ Transmitter:

Generator/ Transmitter:

Battery Condition
Select Continuous. Good batteries will be shown by a loud, clear
audio tone. Bad batteries give an interupted audio tone. The display
(if fitted) will show at least two solid segments if the batteries are OK.
Induced Mode
This can only be checked in conjunction with a Locator as described
on the previous page. If the unit does not meet the performance
expected, repeat the test with another Locator to determine whether
the Generator/ Transmitter is at fault.
Connected Mode
Set the minimum output level, insert the Direct Connection Lead
and the long Auxiliary Earth Lead and then connect the red lead
Crocodile Clip to the Auxiliary Earth Lead Crocodile Clip to create
a short circuit. The pitch should change to a low tone.
The leads should be arranged to create an open loop on the ground
of approximately 1 metre in diameter. Check that a signal can be
detected by the Locator in Generator Mode/ Transmitter Mode when
pointed closely at the loop.
NOTE These checks DO NOT guarantee full system performance. If a deterioration in performance
is suspected, the equipment should not be used. It should be returned to C.Scope or a C.Scope
Authorised Service Centre.
54