Summary of Contents for UNISource Corporation FC-8300
Page 1
Operation Manual FC-8300 3.7GHz Frequency Counter FC-8030 3.0GHz Frequency Counter FC-8150 1.5GHz Frequency Counter FC-8030U 3.0GHz Universal Counter FC-8150U 1.5GHz Universal Counter UNISOURCE CORPORATION 1.800.561.8187 information@itm.com www. .com...
Page 2
Introduction Thank you for purchasing our product. Electronic measuring instruments produced by us are high technology products made under strict quality control. We guarantee their exceptional precision and utmost reliability. For proper use of the product, please read this operation manual carefully. Note 1.
7 digit display with one second gate time due to uniquely developed LSI as well as the expanding/reciprocal system. It covers a frequency range from 0.1Hz to 3.7 GHz (FC-8300: 3.7GHz, FC-8030/8030U: 3.0GHz, FC-8150,8150U: 1.5GHz) based on 10MHz time base T.C.O (temperature controlled oscillator) and also...
• TOTAL RANGE : DC to 30 MHz CAPACITY : 0 to 999 999 999 OVER FLOW : “OF” • RPM RANGE : 6 to 600 x 10 RPM , OVER FLOW : “OF” <FC-8150,FC-8030,FC-8300 only> 1.800.561.8187 information@itm.com www. .com...
Page 6
• MAX. INPUT VOLTAGE LEVEL FIG 1. MAX. Input Level. (input A,B) INPUT B. CHARACTERISTICS < FC-8150U, FC-8030U > • FREQUENCY RANGE : 0.1Hz to 100MHz (DC Coupled) 30Hz to 100MHz (AC Coupled) • SENSITIVITY : 0.1Hz to 100MHz: 30mV •...
Page 7
80MHz – 3.0GHz 25mVrms from 80 MHz to 150 MHz FC-8030U 20mVrms from 150MHz to 2.0 GHz 40mVrms from 2.0GHz to 3.0GHz FC-8300 80MHz – 3.7GHz 10mVrms from 80 MHz to 2.0GHz 20mVrms from 2.0GHz to 3.0GHz 30mVrms from 3.0GHz to 3.2GHz 40mVrms from 3.2GHz to 3.5GHz...
• DISPLAY : Nine Digit 0.56" LED with M/n, K/u, Hz, m, Sec, G.T, Hold, and “OF” indicators. Function and Gate time: User Selected. “OF” Display Shown When Count exceeds 999 999 999 • HOLD : In Frequency and Period, TOTAL. Mode measurement in progress is stopped, and the last complete measurement is displayed.
2. INSTALLATION 2-1. Initial Inspection This instrument was carefully inspected both mechanically and electrically before shipment. It should be physically free of damage. To confirm this, the instrument should be inspected for physical damage in transit. Also, check for supplied accessories.
3-1. Controls, indicators and connectors 3-1-1. FC-8150U, FC-8030U Universal Counter ☺ ☺ ☺ ☺ FIG(2) FRONT PANEL GATE INDICATOR : The gate light, when lit, indicates the main gate is open and measurement in progress. RS-232C INDICATOR: TX(transmitting), RX(receiving) blinking(OPTION) OVER FLOW INDICATOR : OF is displayed when overflow.
Page 11
INPUT C, BNC : Input for frequency measurements above 80MHz Female BNC connector terminated in 50Ω. LOW PASS FILTER : With this switch pushed in, the input B is routed through a SWITCH(LPF) low-pass filter with-3dB point of approximately 100KHz. When it is released, the input B signal is applied to the counter.
Page 12
cycles of the input A signal and continuously displays that count. f. T.l (A→B). When this mode is selected, the unit measures the time interval from an edge of the input A signal to an edge of the input B signal. Positive going or Negative going edge of each signal is selected By the slope switches.
Page 13
The external signal should have a voltage range of 1.5V~5 Vrms. RS-232C CONNECTOR : Connector for serial interfacing with computer. 3-1-2. FC-8150, FC-8030 , FC-8300 Frequency Counter FIG.(4) FRONT PANEL GATE INDICATOR : The gate light, when lit, indicates the main gate is open and measurement in progress.
Page 14
LOW PASS FILTER : With this switch pushed in, the input A is routed through a low-pass filter with a -3 dB point of approximately 100 KHz. When it is released, the input A signal is applied to the counter. ATT.
FIG(5) REAR PANEL AC INLET :For connecting of the supplied ac power INT/EXT TIME BASE SELECTOR: Select the time base, switch position EXT. STD.IN provides a nominal 50Ω input impedance path for an external 10 MHz time base. switch position INT.
Below is the basic operating information needed for frequency counter. a. Connect the unit to AC power cord into receptacle on rear panel and plug into AC inlet. b. To Turn on equipment, push power on-off switch on. c. set the function indicator position to FREQ A and Gate time indicator to 1 Sec position.
INPUT C FC-8150, FC-8150U: 80MHz to 1.5GHz FC-8030, FC-8030U: 80MHz to 3.0GHz FC-8300 : 80MHz to 3.7GHz CAUTION THE MAXIMUM INPUT LIMIT TO THIS INPUT IS 3 Vrms MAXIMUM OVER THE INPUT FREQUENCY RANGE. THE X 10 ATTENUATOR DOES NOT APPLY.
UPDATE COUNT IS DISPLAY. 3-6. RPM (Rotation Per Minute) Measurement <FC-8150, FC-8030, FC-8300> a. Apply the signal to be measured to the input A BNC, and then the counter displays the RPM. Maximum count is 999999999. If this is exceed, the overflow message displays as ”OF”...
be equal to or greater than that of input B. And both frequencies must be within the limits given in the "SPECIFICATIONS" section. Frequency ratio is determined by counting the number of input A cycles occurring during a specified number of input B cycles (1.10.100.1000) and applying the result, with a proper decimal point, to the display.
Page 20
. Microsoft Windows 3.1, 95, 98 . Serial port for connection with counter 2) Output Data Formats (1) Baud rate : 9600BPS 1 start bit (0) 8 data bit 1 stop bit (1) NONE PARITY (2) To Frequency counter Command Parameter Terminate Code 'H' : HOLD...
3) Installing Program and using the software Refer to “Readme” file on Software diskette supplied with unit. 4. MAINTENANCE CAUTION IT IS ESSENTIAL FOR SAFETY TO PROPERLY MAINTAIN AND SERVICE THIS INSTRUMENT WARNING VOLTAGES WITHIN THIS INSTRUMENT ARE SUFFICIENTLY HIGH TO ENDANGER LIFE.
Accuracy of radio frequency measurements can be affected by connections between signal source and counter. Main considerations are standing waves and shunt cable capacitance. Standing wave is usually present due to reflections when a transmission line is not terminated in its characteristic impedance. These standing waves may cause damage to the signal source or produce inaccurate measurements, and their effects increase as cable length reaches one-fourth of the wavelength for the frequency being measure.