3. Set the tire pressure with the
Note: The target pressure should be the vehicles recommended tire pressure found on the sticker inside
the driver's door jamb or inside the fuel access door.
4. Turn the Fill Control Valve handle to FILL.
5. Press the
button.
6. When the alarm sounds the cycle is complete.
7. Turn the Fill Control Valve handle to STOP and remove hoses from valve stems.
8. Flip the ON/OFF button to turn inflator off.
Emergency Stopping
Stop the inflation / deflation cycles by pressing any button on the front panel or by turning the Fill Control Valve
handle from FILL to STOP.
Additional Application Modes
The inflator software contains two other fill modes, 'Std' and 'tir', that are not applicable to nitrogen inflation. If one
of these modes is accidentally entered, the system will not purge tires before filling. Please call our customer
service line for assistance
TROUBLESHOOTING / DIAGNOSTIC CODES_____________________________________
The following diagnostic codes are reported via the inflator display.
Problem / Code
Hose connectors leak or
will not seal to the valve
stem
No Display
Inflation process starts
but does not complete
Inflation or deflation is
very slow
E1
E4
E5
E6, E8, E9
E10 or LO
E11
E12
E13
E17
E19
E18, E20,
E21,E22,E23,E28
and
Possible Cause
Hose Connectors are worn
No power connected
Low supply pressure or leaks exist
Inline filter or mesh filters at input or output
ports may be clogged
Unstable or insufficient supply pressure
Over inflation due to blocked hose
Unit powered ON under pressure; i.e., hose is
connected to tire and control valve set to FILL
Pressure sensor error
Under voltage
Over voltage
PCB fault
Lost or corrupted calibration settings
Calibration data corrupted
Capacitive touch interface error
Software error
buttons on the front panel.
Solution
Replace connectors
Switch power on / Plug in / Replace Battery
Check supply pressure and confirm leaks do
not exist
Clean or replace filters
Check supply pressure
Remove blockage or replace hose
Rotate control valve to STOP and cycle the power
ON/OFF again
Contact Customer Service 800-437-4394
Plug in power cord and charge battery
Check power supply
Contact Customer Service 800-437-4394
Contact Customer Service 800-437-4394
Calibration is required. Contact Customer Service
Contact Customer Service
Contact Customer Service