Suunto D5
6. Reference
6.1. Technical specifications
Dimensions and weight:
Length: 53 mm / 2.08 in
•
Width: 53 mm / 2.08 in
•
Height: 16.5 mm / 10.65 in
•
Weight: 90 g / 3.17 oz
•
Operating conditions
Normal altitude range: 0 to 3,000 m / 10,000 ft above sea level
•
Operating temperature (diving): 0 °C to 40 °C / 32 °F to 104 °F
•
Operating temperature (non-diving): -20 °C to +50 °C (-4 °F to +122 °F)
•
Storage temperature: -20 °C to +50 °C / -4 °F to +122 °F
•
Recommended charging temperature: 0 °C to +35 °C / +32 °F to +95 °F
•
Maintenance cycle: 500 hours of diving or two years, whichever comes first
•
NOTE: Do not leave the dive computer in direct sunlight!
Depth gauge
Temperature compensated pressure sensor
•
Accurate to 100 m / 328 ft complying with EN 13319 and ISO 6425
•
Depth display range: 0 to 300 m /0 to 984 ft
•
Resolution: 0.1 m from 0 to 100 m / 1 ft from 0 to 328 ft
•
Temperature display
Resolution: 1 °C / 1.5 °F
•
•
Display range: -20 to +50 °C/-4 to +122 °F
Accuracy: ± 2 °C/± 3.6 °F within 20 minutes of temperature change in temperature range
•
of 0 °C to 40 °C / 32 °F to 104 °F.
Displays in Air / Nitrox dive mode
Oxygen %: 21–99
•
Oxygen partial pressure display: 0.0–3.0 bar
•
CNS%: 0–500% with 1% resolution
•
OTU: 0-1000
•
Other displays
•
Dive time: 0 to 999 min
Surface time: 0 to 99 h 59 min
•
55