TABLE OF CONTENTS 1.0 General Information 1.1 Safety Regulations 1.2 Range of Application 1.3 Operation 1.4 Installation Site 1.5 Assembly 1.6 Electrical 1.7 Start‐Up 1.8 Technical Data 1.9 Engine Data 2.0 Maintenance 2.1 General 2.2 Filter Changes 2.3 Replacement Filters ...
Page 3
Filter cartridge HEPA filters Fan Pressure gauges Starting device with overcurrent protection The drainage pipe placement is optional left or right. The separated oil or the emulsion can be fed back in the machine or collected in a container. OF 1000 ‐ 8000 is a modular system. An efficient central unit can be built up by adding more modules. Safety Regulations When transporting, the device must be standing straight up. Always turn off the current supply before maintaining service. NOTE This product is developed in accordance with the requirements defined in the EEC guidelines. In order to correspond to these quality requirements, executed installations, repair and maintenance work may only be performed by specialists with use of original spare parts. Consult with your local authorized Fumex dealer for spare parts. Range of Application Separation of oil ‐ and emulsion mist ...
Page 4
Clean air Operation Fan HEPA‐Filter: Degree of separation over 99%. Not washable, but easily changeable. Recommended to be changed at a pressure of 3.2 in/wg. Filter 2: Glas fiber filters with aluminium separators. Recommended to be changed at a pressure of 2.0 in/wg. Filter 1: Glas fiber filters with aluminium separators. Recommended to be changed at a pressure of 2.0 in/wg. Intake: Alternatively right or left side. Drainage: Alternatively right or left side. 1.4 Installation OF‐Filter is suitable only for the application intended, in dry areas. Cleaned air is blown out upward. The exhaust may not be covered. Assembly Select the installation with regard to piping as short as possible Make sure there is enough space to perform service and maintenance. Pipe connection can be made either on the right‐ or the left side. When connecting, use only oil‐resistant material in the hoses and connections. Drainage can be to the left‐ or right side. Only one connection per unit. It is important to prevent air being sucked through the drain line. This is solved by a water trap (Siphon type) ...
Page 5
Electrical Electrical connection must be performed by licensed electricians only. Start Stop Start‐Up Make sure the filter cartridges are correctly installed. Packing and handles should be pointing upward. Start the fan and make sure it goes in the right direction. Pressure gauge on the HEPA filter should be 0.01 psi. ...
Page 6
1.8 Technical Data Dimensions OF 1000: Length: 25 “ Width: 28 “ Height: 69 (without fan 50“) Dimensions OF 2000: Length: 25 “ Width: 28 “ Height: 83 “ (without fan 63 “) Dimensions OF 4000: Length: 31 “ Width: 35 ...
Page 7
1.9 Fan Data Operating Voltage/phase: 400Volt / 3~ Capacity OF 1000: 1 Hp Capacity OF 2000: 3 Hp Capacity OF 4000: 5.4 Hp Capacity OF 6000: 3 x 3 Hp Capacity OF 8000: 2 x 5.4 Hp Rotations: 2.900rpm Frequency: 50‐60Hz Safety Class: IP 54 2.0 Maintenance 2.1 General 2.2 Filter Changes ...
Page 8
2.3 Replacement Filters OF 1000 OF 2000 OEU5/9‐8 OEU5‐10 OH13‐22 OEU5/9‐8 OH13‐22 OF 4000 OF 6000 OEU5‐21 3 x OEU5‐10 ...